2.3. Protective performance of the WORK AIR DL001 T U protective device
The System to which this Informative Note refers must be considered Class 2 Personal
Protective Equipment (PPE) as it has been designed and produced to provide limited
protection against the risks of mechanical impact in the event of a fall with impact as
described in Chapter 3.4. For the performance levels achieved by the WORK AIR DL001 T
U Personal Protective Equipment refer to Table 1.
Table 1: Performance of the Device
Chest Area (airbag protector), tested in accordance with the technical specifications
applied, which establish the following requirements:
• Average value 4.5 kN, Value of single blow 6 kN.
Protector
identification
code
Standard used
for the test
method applied
in tests
Temperatur
e [°C]
at which the
protector
was tested
Force transmitted
with impact energy
of
30 J,
Value
Average/Maximum
Distribution of the
force transmitted
with impact energy
of 30 Joule
(Optional test),
Value
Average/Maximum
WORK AIR
DL001 T U.1, .2
EN1621-3:2018
+ 23°C
+23°C
(*)
+40°C
-10°C
Average: < 1.80 kN
Max: < 1.80 kN
Average: < 1.80 kN
Max: < 1.80 kN
(*) after hydrolytic treatment
Back area (airbag protector), tested in accordance with the technical specifications applied:
• Average value ≤ 4.5 kN, Value of single blow ≤ 6 kN.
Protector
identification
code
Standard used
for the test
method applied
in tests
Temperature
[°C]
at which the
protector
was tested
Force transmitted with impact energy of
30 J,
Value
Average/Maximum
WORK AIR
DL001 T U.1, .2
EN1621-2:2014
+23°C
+23°C
(*)
+40°C
-10°C
Average: < 1.80 kN
Max: < 1.95 kN
(*) after hydrolytic treatment
In particular the WORK AIR DL001 T U protective device:
• When triggered covers with an airbag the chest area (DC-Divided Chest), divided chest
protector and the central area of the back (CB - Central Back), central protector covering
only the central area of the back, this type of protector does not offer protection in the
shoulder blade area.
• Gives a “stealth” protection: comfort and ergonomics. This stealth protection is
imperceptible and is triggered when required, offering a high level of comfort and safety.
Protective performance is correlated to choosing the correct size of WORK AIR DL001 T U,
following the guidelines provided in Chapter 2.5.