Specifications

Application
This is used to locate faulty linearity of the video
amplier
or greyscale
setting. Nonlinearities mainly result in a compression of the white level.
Black White Line
P19 Vertical BW1 (black 1 pixel, white 1 pixel)
P20
Vertical BW12(black 12 pixels, white 12
pixels)
P21 Horizontal BW1(black 1 pixel, white 1 pixel)
P22
Horizontal BW3(black 3 pixels, white 3
pixels)
P23
Horizontal BW6(black 6 pixels, white 6
pixels)
P24 Multi-Burst BW6+BW3+BW2+BW1
Application
The Vertical pattern serves for a quick check of a color monitor
s horizontal
bandwidth and phase behavior of a video transmission. It also, verify video
ampli
er
and color temperature.
The Horizontal pattern serves for a quick check of color monitor
s vertical
bandwidth and
phase behavior of a video transmission. It also, verify video amp
li
er and
color temperature.
PLUGE
P25
Picture Line-Up Generation Equipment
Press [OPTION] to select color range
Full Range=0~255, Limited Range=16~235
PC/HD output gets Full Range=0%~100%
Application
PLUGE is used to perform accurate and consistent line-up of picture
monitors. The usual procedure is to adjust the brightness control of a
monitor so that bar 1 is invisible on the background while bar 2 can be still
distinguished. The white level luminance is mainly
adjusted by the contrast control to 70
±
10 cd/m2 by means of the upper
100% white area of the vertical grayscale.
18