Specifications

© 2010 Cypress Solutions Complete Manual: CTM-15X Firmware 1.3.0
Open CTM (Revision D)
71
Command Reference
l = 0 disables the local report (default)
l = 1 asynchronous NMEA or ULCP messages over RS232
l = 2 asynchronous NMEA or ULCP messages with a ULCP header over RS232
l = 3 in-band NMEA or ULCP messages in a UDP Packet over Ethernet
l = 4 in-band NMEA or ULCP messages with a ULCP header and in individual UDP packets over Ethernet
l = 5 in-band NMEA or ULCP messages in a TCP Packet over Ethernet
l = 6 file-based reports
r = 0 disables the remote report (default)
r = 3 in-band NMEA or ULCP messages in a UDP Packet
r = 4 in-band NMEA or ULCP messages with a ULCP header and in individual UDP packets
r = 5 in-Band NMEA or ULCP messages in a TCP Packet
r = 6 email reports
r = 7 SMS reports
s = 0 disables the store and forward of IO reports
s = 1 enables the store and forward of IO reports
Note: For r = 7 (SMS reports), the total length of the report must not exceed 166 characters including
<CR> and <LF>
The current report configuration for an IO report can be queried by using iorep n where n is the report
number.
If n is omitted, all reports will be queried.
Examples: cmd iorep 4 3 3 this will send IO report #4 as a UDP packet over Ethernet and over the wireless
link, and will not store IO reports
cmd iorep 2 3 7 1 this will send IO report #2 as a UDP packet over Ethernet and as an SMS message to the
SMS destination set using the iosms command, and will enable the store and forward of IO reports
cmd iorep queries the reporting method for all IO reports
A cmd save is required for this command to take effect.
return to list of commands
iosms n pppppppppp or <email address>
Sets the destination of the IO report that is sent as an SMS message. Up to 8 IO reports may be
configured. The default SMS destination is blank.
Note: SMS features are only available for specific manufacturer, RF modules, cards or devices. Please
contact Cypress Solutions for a complete list of products that support SMS functionality.
n = 1 to 8 IO report number