Specifications
© 2010 Cypress Solutions Complete Manual: CTM-15X Firmware 1.3.0
Open CTM (Revision D)
65
Command Reference
n = 1 to 8 ignition trigger condition
r = 1 to 999 report number
r = 0 disables the report
Example:
1. Set report #2 for ignition trigger condition #1.
cmd ignreport 1 2
OK
A cmd save is required for this command to take effect.
See also: igncond, repaddmes, repdelmes, repemail, replocport, repremip, repremport, repsms, reptype
return to list of commands
input
Reads the value and state of all inputs. There are a total of six inputs.
Both the analog voltage (range 0 to 10 Volts) and digital state (0 for off and 1 for on) are returned.
This is a read only command.
Example:
1. Query the current status of input #1 through #6
cmd input
0.00V 0
0.00V 0
0.00V 0
0.08V 0
0.08V 0
0.08V 0
OK
return to list of commands
insetup n d x.x p a
Configures the six inputs. Their use as a digital or analog input can be set along with their alarm states.
Note: Voltage threshold values are accurate to one decimal place, (X.X), if additional decimal place values
are entered, they will be rounded to the nearest decimal place.