DC Electrical Characteristics
DC Chip Level Specifications
Tab l e 9 lists guaranteed maximum and minimum specifications for the entire voltage and temperature ranges.
Table 9. DC Chip Level Specifications
Symbol Description Conditions Min Typ Max Units
V
DD
Operating voltage
[7, 9]
No USB activity. 3.0 5.5 V
I
DD24,3
Supply current, CPU = 24 MHz Conditions are V
DD
= 3.0 V, T
A
= 25 C,
CPU = 24 MHz,
No USB/I
2
C/SPI.
2.9 4.0 mA
I
DD12,3
Supply current, CPU = 12 MHz Conditions are V
DD
= 3.0 V, T
A
= 25 C,
CPU = 12 MHz,
No USB/I
2
C/SPI.
1.7 2.6 mA
I
DD6,3
Supply current, CPU = 6 MHz Conditions are V
DD
= 3.0 V, T
A
= 25 C,
CPU = 6 MHz,
No USB/I
2
C/SPI.
1.2 1.8 mA
I
SB1,3
Standby current with POR, LVD, and sleep
timer
V
DD
= 3.0 V, T
A
= 25 C, I/O regulator
turned off.
1.1 1.5 A
I
SB0,3
Deep sleep current V
DD
= 3.0 V, T
A
= 25 C, I/O regulator
turned off.
0.1 A
V
DDUSB
Operating voltage USB activity, USB regulator enabled 4.35 5.25 V
I
DD24,5
Supply current, CPU = 24 MHz Conditions are V
DD
= 5.0 V, T
A
= 25 C,
CPU = 24 MHz, IMO = 24 MHz
USB Active, No I
2
C/SPI.
7.1 mA
I
DD12,5
Supply current, CPU = 12 MHz Conditions are V
DD
= 5.0 V, T
A
= 25 C,
CPU = 12 MHz, IMO = 24 MHz
USB Active, No I
2
C/SPI.
6.2 mA
I
DD6,5
Supply current, CPU = 6 MHz Conditions are V
DD
= 5.0 V, T
A
= 25 C,
CPU = 6 MHz, IMO = 24 MHz
USB Active, No I
2
C/SPI
5.8 mA
I
SB1,5
Standby current with POR, LVD, and sleep
timer
V
DD
= 5.0 V, T
A
= 25 C, I/O regulator
turned off.
1.1 A
I
SB0,5
Deep sleep current V
DD
= 5.0 V, T
A
= 25 C, I/O regulator
turned off.
0.1 A
V
DDUSB
Operating voltage USB activity, USB regulator bypassed 3.15 3.3 3.60 V