Specifications

78 CY3214-PSoCEVALUSB Kit Guide, Doc No. 001-67030 Rev. *B
Code Examples
5.8.5 Verify Output
1. Program the board with USBUART.hex from <Install_Directory>:\Cypress\CY3214-
PSoCEVALUSB\<version>\Firmware\USBUART\USBUART, as explained in Programming
Specifications and Connections on page 16.
2. On successful programming, disconnect the MiniProg1 and connect a USB cable from the board
to a free USB port on PC.
3. When connecting for the first time, wait for the device to be installed.
4. Ignore the Digital Signature warning when prompted; click on Continue Anyway.
5. Check the Device Manager for the comm port number allotted for USBUART device.
6. Open HyperTerminal and connect to the required comm port.
7. Set the comm port settings as follows: 19200-N-8-1. FlowControl: None.
Figure 5-76. HyperTerminal Settings
An echoed message displays on the HyperTerminal.
Notes
The local echoing of transmit data in HyperTerminal is disabled by default. (See File > Proper-
ties > Settings > ASCII Setup)
If enabled, two instances of every character transmitted are seen in the HyperTerminal: once due
to local echoing and the other is the received data