Datasheet

CY8C21634/CY8C21534/CY8C21434
CY8C21334/CY8C21234
Document Number: 38-12025 Rev. AF Page 30 of 55
AC External Clock Specifications
The following tables list the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75 V to
5.25 V and –40 °C T
A
85 °C, or 3.0 V to 3.6 V and –40 °C T
A
85 °C, respectively. Typical parameters are measured at 5 V,
3.3 V, or 2.7 V at 25 °C and are for design guidance only.
Table 22. 2.7-V AC Digital Block Specifications
Function Description Min Typ Max Units Notes
All
functions
Block input clock frequency 12.7 MHz 2.4 V < V
DD
< 3.0 V
Timer Capture pulse width 100
[38]
ns
Input clock frequency, with or without capture 12.7 MHz
Counter Enable input pulse width 100 ns
Input clock frequency, no enable input 12.7 MHz
Input clock frequency, enable input 12.7 MHz
Dead Band Kill pulse width:
Asynchronous restart mode 20 ns
Synchronous restart mode 100 ns
Disable mode 100 ns
Input clock frequency 12.7 MHz
CRCPRS
(PRS Mode)
Input clock frequency 12.7 MHz
CRCPRS
(CRC Mode)
Input clock frequency 12.7 MHz
SPIM Input clock frequency 6.35 MHz The SPI serial clock (SCLK)
frequency is equal to the input
clock frequency divided by 2.
SPIS Input clock (SCLK) frequency 4.1 MHz
Width of SS_ Negated between transmissions 100 ns
Transmitter Input clock frequency 12.7 MHz The baud rate is equal to the input
clock frequency divided by 8.
Receiver Input clock frequency 12.7 MHz The baud rate is equal to the input
clock frequency divided by 8.
Table 23. 5-V AC External Clock Specifications
Symbol Description Min Typ Max Units Notes
F
OSCEXT
Frequency 0.093 –24.6MHz
High period 20.6
5300 ns
Low period 20.6
–ns
Power-up IMO to switch 150
–µs