Datasheet

CY7C1543V18
CY7C1545V18
Document Number: 001-05389 Rev. *H Page 21 of 26
Capacitance
Tested initially and after any design or process change that may affect these parameters.
Parameter Description Test Conditions Max Unit
C
IN
Input Capacitance T
A
= 25C, f = 1 MHz, V
DD
= 1.8V, V
DDQ
= 1.5V 5 pF
C
CLK
Clock Input Capacitance 6 pF
C
O
Output Capacitance 7pF
Thermal Resistance
Tested initially and after any design or process change that may affect these parameters.
Parameter Description Test Conditions
165 FBGA
Package
Unit
JA
Thermal Resistance
(Junction to Ambient)
Test conditions follow standard test methods and
procedures for measuring thermal impedance, in
accordance with EIA/JESD51.
11.82 °C/W
JC
Thermal Resistance
(Junction to Case)
2.33 °C/W
Figure 4. AC Test Loads and Waveforms
1.25V
0.25V
R = 50
5pF
INCLUDING
JIG AND
SCOPE
ALL INPUT PULSES
Device
R
L
= 50
Z
0
= 50
V
REF
= 0.75V
V
REF
= 0.75V
[23]
0.75V
Under
Tes t
0.75V
Device
Under
Tes t
OUTPUT
0.75V
V
REF
V
REF
OUTPUT
ZQ
ZQ
(a)
Slew Rate = 2 V/ns
RQ =
250
(b)
RQ =
250
Note
23. Unless otherwise noted, test conditions assume signal transition time of 2V/ns, timing reference levels of 0.75V, Vref = 0.75V, RQ = 250, V
DDQ
= 1.5V, input pulse
levels of 0.25V to 1.25V, and output loading of the specified I
OL
/I
OH
and load capacitance shown in (a) of AC Test Loads and Waveforms.
[+] Feedback