Specifications
CY14C101PA
CY14B101PA
CY14E101PA
Document Number: 001-54392 Rev. *N Page 32 of 44
I
OZ
Off state output leakage
current
–1 – +1 A
V
IH
Input HIGH voltage CY14C101PA 1.7 – V
CC
+ 0.5 V
CY14B101PA 2.0 – V
CC
+ 0.5 V
CY14E101PA
V
IL
Input LOW voltage CY14C101PA V
ss
– 0.5 – 0.7 V
CY14B101PA V
ss
– 0.5 – 0.8 V
CY14E101PA
V
OH
Output HIGH voltage I
OUT
= –1 mA CY14C101PA 2.0 – – V
I
OUT
= –2 mA CY14B101PA 2.4 – – V
CY14E101PA V
CC
– 0.4 – –
V
OL
Output LOW voltage I
OUT
= 2 mA CY14C101PA – – 0.4 V
I
OUT
= 4 mA CY14B101PA – – 0.4 V
CY14E101PA
V
CAP
[10]
Storage capacitor Between V
CAP
pin and V
SS
CY14C101PA 170 220 270 F
CY14B101PA 42 47 180 F
CY14E101PA
V
VCAP
[11, 12]
Maximum voltage driven
on V
CAP
pin by the device
V
CC
= Max CY14C101PA – – V
CC
V
CY14B101PA
CY14E101PA – – V
CC
– 0.5 V
Data Retention and Endurance
Over the Operating Range
Parameter Description Min Unit
DATA
R
Data retention 20 Years
NV
C
Nonvolatile STORE operations 1,000 K
DC Electrical Characteristics (continued)
Over the Operating Range
Parameter Description Test Conditions Min Typ
[8]
Max Unit
Capacitance
Parameter
[12]
Description Test Conditions Max Unit
C
IN
Input capacitance T
A
= 25 C, f = 1 MHz, V
CC
= V
CC(Typ)
7pF
C
OUT
Output pin capacitance 7pF
Notes
10. Min V
CAP
value guarantees that there is a sufficient charge available to complete a successful AutoStore operation. Max V
CAP
value guarantees that the capacitor on
V
CAP
is charged to a minimum voltage during a Power-Up RECALL cycle so that an immediate power-down cycle can complete a successful AutoStore. Therefore it
is always recommended to use a capacitor within the specified min and max limits. Refer application note AN43593 for more details on V
CAP
options.
11. Maximum voltage on V
CAP
pin (V
VCAP
) is provided for guidance when choosing the V
CAP
capacitor. The voltage rating of the V
CAP
capacitor across the operating
temperature range should be higher than the V
VCAP
voltage.
12. These parameters are guaranteed by design and are not tested.