User`s manual
X5-GSPS XMC Module
Environmental
Table 18. X5-GSPS Environmental Limits
Condition Limits
Operating Ambient Temperature 0 to 55 C
Humidity 5 to 95 %, non condensing
Storage Temperature -30 to 85 C
Forced Air Cooling Dependent on application
Vibration, operating ETS 300 019- 1.3 [R3], class 3.3
Vibration, storage ETS 300 019- 1.1 [R1], class 1.2
Vibration, transportation ETS 300 019- 1.2 [R2], class 2.3
except for free-fall: class 2.2
Analog Input
A summary of the analog performance follows for the X5-GSPS module.
All tests performed at room temperature, with no forced air cooling unless noted. Test environment was PCIe adapter card in
PC running testbed software using FrameWork Logic.
Table 19. X5-GSPS Analog Performance Summary
Test Group Parameter Measured Units Test Conditions
Analog Input Impedance 50 Ohms nominal
Input Range 2 Vp-p Standard on X5-GSPS, calibration results may limit input
range to 0.99 of full scale nominal.
Accuracy Offset <10 mV Factory calibration, average of 64K samples
Gain 0.02 % Factory calibration, average of 64K samples
Analog Input Ground Noise 31 mVp-p Input Grounded, Fs = 1497 MSPS, 128K samples
Ground Noise
Floor
-82 dB Input Grounded, Fs = 1497 MSPS, 64K sample FFT, non-
averaged
Analog Input Crosstalk -71 dB Worst case, Fin = 101 MHz, 2V p-p input
X5-GSPS User's Manual 90