Datasheet

CY7C1292DV18
CY7C1294DV18
Document #: 001-00350 Rev. *E Page 21 of 26
Switching Characteristics
Over the Operating Range
[23, 24]
Cypress
Parameter
Consortium
Parameter
Description
250 MHz 200 MHz 167 MHz
Unit
Min. Max. Min. Max. Min. Max.
t
POWER
t
KHKH
V
DD
(Typical) to the first Access
[25]
111ms
t
CYC
t
KHKL
K Clock and C Clock Cycle Time 4.0 6.3 5.0 7.9 6.0 7.9 ns
t
KH
t
KLKH
Input Clock (K/K and C/C) HIGH
1.6 2.0 2.4 ns
t
KL
t
KHKH
Input Clock (K/K and C/C) LOW
1.6 2.0 2.4 ns
t
KHKH
t
KHCH
K Clock Rise to K Clock Rise and C to C Rise
(rising edge to rising edge)
1.8 2.2 2.7 ns
t
KHCH
t
KHKH
K/K Clock Rise to C/C Clock Rise
(rising edge to rising edge)
0.0 1.8 0.0 2.2 0.0 2.7 ns
Setup Times
t
SA
t
AVKH
Address Setup to Clock (K/K) Rise 0.35 0.4 0.5 ns
t
SC
t
IVKH
Control Setup to K Clock Rise (RPS, WPS)
0.35 0.4 0.5 ns
t
SCDDR
t
IVKH
Double Data Rate Control Setup to Clock
(K/K
) Rise (BWS
0
, BWS
1
, BWS
3
, BWS
4
) 0.35 0.4 0.5 ns
t
SD
t
DVKH
D
[X:0]
Setup to Clock (K/K) Rise
0.35 0.4 0.5 ns
Hold Times
t
HA
t
KHAX
Address Hold after Clock (K/K) Rise
0.35 0.4 0.5 ns
t
HC
t
KHIX
Control Hold after K Clock Rise (RPS, WPS)
0.35 0.4 0.5 ns
t
HCDDR
t
KHIX
Double Data Rate Control Hold after Clock
(K/K
) Rise (BWS
0
, BWS
1
, BWS
3
, BWS
4
) 0.35 0.4 0.5 ns
t
HD
t
KHDX
D
[X:0]
Hold after Clock (K/K) Rise
0.35 0.4 0.5 ns
Output Times
t
CO
t
CHQV
C/C Clock Rise (or K/K in Single Clock Mode) to
Data Valid
0.45 0.45 0.50 ns
t
DOH
t
CHQX
Data Output Hold after Output C/C Clock Rise
(Active to Active)
–0.45 -0.45 -0.50 ns
t
CCQO
t
CHCQV
C/C Clock Rise to Echo Clock Valid
0.45 0.45 0.50 ns
t
CQOH
t
CHCQX
Echo Clock Hold after C/C Clock Rise
0.45 –0.45 –0.50 ns
t
CQD
t
CQHQV
Echo Clock High to Data Valid 0.30 0.35 0.40 ns
t
CQDOH
t
CQHQX
Echo Clock High to Data Invalid –0.30 –0.35 –0.40 ns
t
CHZ
t
CHQZ
Clock (C/C) Rise to High-Z
(Active to High-Z)
[26,27]
0.45 0.45 0.50 ns
t
CLZ
t
CHQX1
Clock (C/C) Rise to Low-Z
[26,27]
–0.45 –0.45 –0.50 ns
DLL Timing
t
KC Var
t
KC Var
Clock Phase Jitter 0.20 0.20 0.20 ns
t
KC lock
t
KC lock
DLL Lock Time (K, C) 1024 1024 1024 cycles
t
KC Reset
t
KC Reset
K Static to DLL Reset 30 30 30 ns
Notes
24. All devices can operate at clock frequencies as low as 119 MHz. When a part with a maximum frequency above 133 MHz is operating at a lower clock frequency, it
requires the input timings of the frequency range in which it is being operated and outputs data with the output timings of that frequency range.
25. This part has a voltage regulator internally; t
POWER
is the time that the power needs to be supplied above V
DD
minimum initially before a read or write operation can
be initiated.
26. t
CHZ
, t
CLZ
, are specified with a load capacitance of 5 pF as in (b) of AC Test Loads. Transition is measured 100 mV from steady-state voltage.
27. At any given voltage and temperature t
CHZ
is less than t
CLZ
and t
CHZ
less than t
CO
.