Datasheet
CY7C1292DV18
CY7C1294DV18
Document #: 001-00350 Rev. *E Page 20 of 26
AC Input Requirements
Over the Operating Range
Parameter Description Test Conditions Min Typ Max Unit
V
IH
Input HIGH Voltage V
REF
+ 0.2 – – V
V
IL
Input LOW Voltage – – V
REF
- 0.2 V
Capacitance
Tested initially and after any design or process change that may affect these parameters.
Parameter Description Test Conditions Max Unit
C
IN
Input Capacitance T
A
= 25C, f = 1 MHz,
V
DD
= 1.8V
V
DDQ
= 1.5V
5pF
C
CLK
Clock Input Capacitance 6 pF
C
O
Output Capacitance 7 pF
Thermal Resistance
Tested initially and after any design or process change that may affect these parameters.
Parameter Description Test Conditions 165 FBGA Unit
JA
Thermal Resistance (Junction to Ambient) Test conditions follow standard test
methods and procedures for measuring
thermal impedance, per EIA/JESD51.
28.51 C/W
JC
Thermal Resistance (Junction to Case) 5.91 C/W
Figure 4. AC Test Loads and Waveforms
1.25V
0.25V
R = 50
5pF
ALL INPUT PULSES
Device
R
L
= 50
Z
0
= 50
V
REF
= 0.75V
V
REF
= 0.75V
[23]
0.75V
Under
Tes t
0.75V
Device
Under
Tes t
OUTPUT
0.75V
V
REF
V
REF
OUTPUT
ZQ
ZQ
(a)
Slew Rate = 2 V/ns
RQ =
250
(b)
RQ =
250
Note
23. Unless otherwise noted, test conditions assume signal transition time of 2V/ns, timing reference levels of 0.75V, Vref = 0.75V, RQ = 250, V
DDQ
= 1.5V, input pulse
levels of 0.25V to 1.25V, and output loading of the specified I
OL
/I
OH
and load capacitance shown in (a) of AC Test Loads and Waveforms.