Specifications
CAK50/CAK61 SERIES ERROR! USE THE HOME TAB TO APPLY 标题 1 TO THE TEX
SHENYANG MACHINE TOOL CO., LTD 59
7.5.1.2 Abnormal Temperature Rising in the Headstock
Lubricating inside the headstock is bad.
Pre-tightening force of spindle bearings is not proper.
7.5.1.3 Zero Points of X-axis and Z-axis Disappear
The switch for zero point is loose.
7.5.1.4 Bad Accuracy of Repeatability
Adjustment of the gib is not proper.
Lubrication of the guideways is not proper.
The screws of the couple and the expansion sleeve are loosened.
7.5.1.5 The machine does not work
NC device displays alarm signal.
There may be damage on some part.
7.5.1.6 The Jaws of Chuck Do not Work
The value set by pressure-relief valve for adjusting chucking force is not correct.
Open /close solenoid of the jaws does not normally work.
Function of the foot-brake is abnormal.
Relay corresponding to action of the foot-brake works abnormally.
The wedges and the jaws are not firmly clamped.
7.5.1.7 Travel of the hydraulic jaws is short.
Check if there are a lot of chips inside.
Check if the rotary oil cylinder and the connecting rod are loose.
7.5.1.8 Taper on the Finished Workpiece Appears
(When plate-type workpiece is turned)
Centering of headstock is not proper.
(When shaft workpiece is turned).
Centering of tailstock is not proper.
Check if it has got good installing accuracy.