Specifications

CAK50/CAK61 SERIES ERROR! USE THE HOME TAB TO APPLY 标题 1 TO THE TE
X
SHENYANG MACHINE TOOL CO., LTD 47
Whenever the system pressure is lower than 0.7Mpa, the pressure relay will send
signal.
5.2.7.2.1.2 Pneumatic Chuck
The machine employs pneumatic chuck, and when the electromagnet YV1 of the
electromagnetic conversing valve is electrifying, the chuck will clamp. When the
electromagnet YV2 of the electromagnetic conversing valve is electrifying, the
chuck will release. The clamping pressure of pneumatic chuck is determined by
the system pressure.
5.2.7.2.2 Operation and Maintenance of Pneumatic System
5.2.7.2.2.1 Element Installation
It is necessary to install the triple-connector of air resource vertically, and the
installation shall be carried out according to the direction shown by the arrow on
the bracket: let the compressed air enter into the filter, pressure-adjust section and
oil atomizer in turn.
5.2.7.2.2.2 Pressure Adjustment
Before switch on the air, it is necessary counter-clockwise to turn the handle of
triple-connector until the pressure-adjust spring is under the free status. Then turn
on the inlet valve on the pipeline to let air in, turn pressure-adjust handle clockwise
until the reading on the pressure gauge is up to the required.
5.2.7.2.2.3 Adjustment of Oil Drop
The required oil-drop amount can be obtained through adjusting the needle-type
valve of the triple-connector.
5.2.7.2.2.4 Maintenance
Connect the drainpipe under the filter into the specified container. And clean the
filtering net, the water cup and the oil cup according the practical working
condition.