Specifications

3
6. OPERATION CONTROLS AND FUNCTIONS
6.1 Front Panel
7
IR
PowerAll LockEnter
12
5678
34
1 2 3 4 5 6
8x8 IR Matrix
1
LCM: Displays the setting information of each input and output
setting.
2
IR: IR Receiver window (accepts the remote control signal of this
device only).
3
Power: Press this button to power the device on/off. The LED will
illuminate green when the power is on, red when it is in 'Standby'
mode.
4
All: Press this button to select all IR output with one IR input signal.
The sequence should be: ALL
Number Key
ENTER.
5
Lock: Press this button to lock all the buttons on the panel; press
again to unlock. The LED will illuminate green when locked.
6
Enter: Press this button to conrm when changing a setting. If this
button is not pressed within 20 seconds the selection is cancelled.
7
1~8/A~H: Use these buttons to select which source is selected for
control in each output location. Press a number key to select fromt
TV A to TV H channels and press a number key again to select
from Source 1 to Source 8 channels. Press 'Enter' to conrm the
selection.
Note: Press 'All', 'Enter' and '1' together to switch the RS-232 baud
rate to 9600 bps or press 'All', 'Enter' and '2' together to switch
baud rate to 19200 bps. The LCM will display the current baud rate
setting for few seconds.