User Guide

© 2022 CYCMOTOR LTD
THROTTLE
RAMPING TIME
This is the time it takes for the motor to achieve the
required input. For example, if you open the throttle
fully, it will take 250ms (by default) before the motor
gives you full power. It will gradually ramp up to full
power within the set time. We recommend not to set
this below 150ms.
INPUT DEADBAND
This value pertains to opening the throttle when it’s
completely closed. This is the amount of throttle can
be moved from the zero position without generating a
response from the motor. If this value is set lower, your
throttle will engage quicker and vice versa.
MAX VOLTAGE
This value should be the same as the Throttle Voltage
Reading when the throttle is closed and sets the
output when it is not active.
MIN VOLTAGE
This is the output of the throttle when opened fully
and is pre-set when purchased. This does not need
any change with CYC supplied throttles.
THROTTLE AUTO SETUP
If you’d like to use your own throttle, this will
automatically setup the minimum and maximum
voltage accordingly. Follow the steps as prompted on
the screen.