Installation Guide
9Cyclone Undermount Installation - English
Preparation for Vent and Exhaust Duct Connection
1.  To connect a rectangular vent to a round exhaust duct (or vice 
versa), use a connecting duct and adapter.
2.  e round vent of a Cyclone Range Hood is 6” diameter. If 
the round exhaust duct is not 6” diameter, a connecting duct 
is necessary to accommodate the dierent size. If the exhaust 
duct is less than 6” diameter, the eciency of your Cyclone 
Range Hood will be reduced and the warranty may be voided.
3.  If the rectangular vent is being connected to an existing rectangular 
duct, a connecting duct is not needed. However, a professional 
should be consulted to install the range hood properly.
4.  An exhaust duct needs to be cut if there is not an existing duct in 
your home. Please consult/hire a professional to complete the 
work properly. In general, for rear venting, a rectangular hole 
needs to be cut into the wall to t the rectangular exhaust duct 
extended to the outside wall. For top venting, a rectangular or 
a 6” round hole needs to be cut through the ceiling or the back 
wall and the bottom of the cabinet to t the duct connection.
Install the Undermount Hood
1.  Place the range hood on the bottom of the cabinet. Route 
the power supply cord through the access hole and through 
the knockout. is step will have to be accomplished while 
positioning the hood (Figure 6 & 7).
2.  Center the hood in place beneath the 
cabinet and ush with the front of 
the cabinet. Outline the four keyhole 
mounting slots for the hood onto the 
bottom of the cabinet. 
3.  Partially screw in the four hood 
mounting wood screws through the 
narrow ends of the marked keyholes. 
4.  Align the hood’s wider ends of the 
keyholes mounting slots over the four 
partially installed screws. Push the hood against the wall 
so that the screws are now secured in the narrow end of the 
keyhole and that the front of the hood is aligned with the 
cabinet front (Figure 7). 
5.  Check to ensure the rear or top vent is tted and connected to 
the duct properly. Use aluminum foil tape to cover all seams.
Knockout
Opening
Mounted Strips
Width of 
Range Hood
Keyhole
Slot Outline
6.  Tighten the hood mounting screws all the way into the cabinet 
so the hood is rmly attached.
7.  Make the Electrical Connection
i.  Secure the electrical wire to the hood with the connector’s  
“STAR” locknut.
ii.  Strip about ½” of insulation from the ends of the electrical 
power wires.
iii.  Connect the power line ground wire to the green ground 
wire supplied with the hood (Figure 8).
iv.  Connect the black power wire to the black wire supplied 
with the hood.
v.  Complete the same step with the white wire.
8.  Reinstall the hood cover plate with the insert screws. For 
NA330R, no screws are needed. Place bae lters back on.
9.  Attach the rectangular and round oil collectors at the far 
back and under the fan guard respectively. For NA330R, oil 
collector is already installed.
10.  Turn on the hood to check for any leaks in the ductwork and 
to ensure proper function. 
Figure 6.
Figure 7.
Figure 8.
Junction Box
Range Hood Connection
Power Line Connection
Range Hood Front
Electrical Knockout