6 Cyclone Undermount Installation - English
MOUNTING HEIGHTS AND CLEARANCE
•  e hood should be installed at 28” minimum above the 
cooking surface. If pairing your range hood with a gas 
stove minimum mounting height must be 30” above the 
cooking surface.
WARNING
Minimum mount height between range top to hood bottom should 
be no less than 28” for electric or ceramic stoves, and no less than 30” 
for gas stoves. e maximum mount height should be no more than 
36”. e hood must be installed at the correct mounting height. Hoods 
mounted too low could result in heat damage. Hoods mounted too 
high, on the other hand, will be less eective and performance may 
suer.
Check your ceiling height and the hood height maximum before 
you select your hood.
Hood installation height above cook top is the user’s preference.  
e lower the hood is above the cook top the more ecient it will 
be in drawing out cooking odors, grease and smoke.
Min:
Ceramic/Electric 
28”
Gas   30”
Max:
 36”
36”
Ceramic/Electric 28”
Max:
 36”
Gas   30”
Min:
WIRING INSTALLATION
Grounding Instructions 
is appliance must be grounded. 
is appliance is equipped with a cord having a grounding wire or 
with a plug having grounding wire. e grounding wire must be 
grounded properly in the junction box or the plug must be plugged 
into an outlet that is properly installed and grounded.
1.  Connect the power line ground wire to the green ground wire 
supplied with the hood. 
2.  Connect the black power wire to the black wire supplied with 
the hood.
3.  Connect the white neutral wire to the white wire supplied with 
the hood.
Max. 36”
Min. 2 ¾”
Install the Electrical Power Supply (PTB8 series only)
Position the outlet or junction box within the space covered by 
the upper cabinet or optional chimney ue. Place the outlet or 
junction box at a maximum distance of 36” above from where the 
cord exits from the hood. e center of the outlet or junction box 
should be positioned at no less than 2 ¾” away from the center of 
the damper. Make sure this does not interfere with the mounting 
area, ducting or chimney ue. 
Green: Ground
White: Neutral
Black: Power
is appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected 
by a circuit breaker or time delay fuse.