Self-Cleaning Range Hoods Insert Range Hoods Models: BX212, BX215, BX155, BX600, CLX60, BOX2000, SS130 Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local electrical codes.
Cyclone Insert Installation - English
IMPORTANT SAFETY INSTRUCTIONS WARNING • • • This appliance must be installed by a qualified technician. The manufacturer declines all responsibilities in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence, and the warranty of the unit automatically expires due to improper installation and maintenance.
CONTENTS 4 Important Safety Instructions 3 Damage Inspection 5 Ducting 5 Mounting Heights and Clearance 6 Wiring Installation 6 Tools and Materials Required 7 BX2000/BX2010 Installation - Parts supplied 8 BX2000/BX2010 Insert Hood Installation 9 SS130 Installation - Parts supplied 11 SS130 Insert Hood Installation 12 SS130 Installation - Installation Cutout Templates 13 BX212/BX215 Installation - Parts supplied 14 BX212/BX215 Insert Hood Installation 15 BX212/BX215 I
DAMAGE INSPECTION • • • • Please fully inspect unit for damage before installation. If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement. If the unit is damaged by the customer, repair or replacement is the responsibility of the customer. If the unit is damaged by the installer (if other than the customer), repair of replacement must be made by arrangement between customer and installer.
MOUNTING HEIGHTS AND CLEARANCE WARNING • The hood should be installed at 28” minimum above the cooking surface. If pairing your range hood with a gas stove minimum mounting height must be 30” above the cooking surface. Minimum mount height between range top to hood bottom should be no less than 28” for electric or ceramic stoves, and no less than 30” for gas stoves. The maximum mount height should be no more than 36”. The hood must be installed at the correct mounting height.
Preparation for Vent and Exhaust Duct Connection Ducting Connection 1. When there is no access to the top of the hood, carefully pull down the metal duct through the custom hood base hole. Slide this duct over the adapter/damper. Make sure the adapter/damper assembly enters the ducting. Seal the connection with aluminum tape. 2. 3. To connect a rectangular vent to a round exhaust duct (or vice versa), use a connecting duct and adapter. The round vent of a Cyclone Range Hood is 6” diameter.
BX2000/BX2010 INSTALLATION - PARTS SUPPLIED 1 × Hood 2 × Round Oil Collectors 2 × Rectangular Oil Collectors BX2010 ONLY: 1 × Rectangular Damper HARDWARE PACKAGE 4 × Mounting Screws 8 BX2010 ONLY: 6 × Damper Screws Cyclone Insert Installation - English BX2000 ONLY: 2 × Halogen Lights (120V, 20W per bulb) BX2010 ONLY: 1 × Halogen Lights
BX2000/BX2010 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. WARNING • CAUTION • • At least two installers are required due to the weight and size of the hood. Turn off power circuit at the service panel before wiring this unit. All electrical work must be done by a qualified electrician in accordance with all applicable codes and standards.
Install the BX2000/BX2010 Hood 1. 2. 3. 4. Place the top of the range hood against the bottom of the cabinet. Route the power supply cord through the access hole and through the knockout. This step will have to be accomplished while Figure 5. positioning the hood (Figure 5 & 6). Center the hood in place beneath the cabinet and align with the front of the cabinet. Outline the four keyhole mounting slots for the hood onto the bottom of the cabinet.
SS130 INSTALLATION - PARTS SUPPLIED 1 × Hood 1 × Round Adapter 1 × Rectangular Oil Collector PRE-INSTALLED 2 × LED Lights (1.5W per bulb) *Bulb & socket may change.
SS130 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • • 1. 2. 3. At least two installers are required due to the weight and size of the hood. WARNING • Install the SS130 Range Hood Remove outer mesh filters of range hood Attach damper to rectangular cutout on top of the range hood using the screws provided.
SS130 INSTALLATION - INSTALLATION CUTOUT TEMPLATES SS13024 SS13030 Cyclone Insert Installation - English 13
BX212/BX215 INSTALLATION - PARTS SUPPLIED 1 × Hood 1 × Round Adapter 1 × Rectangular Oil Collector 1 × Plastic Adapter Seal HARDWARE PACKAGE 4 × Mounting Screws 14 6 × Adapter Screws Cyclone Insert Installation - English INCLUDED IN UNIT 2 × Halogen Lights (120V, 20W per bulb)
BX212/BX215 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. CAUTION • At least two installers are required due to the weight and size of the hood. Installing the BX212/BX215 Range Hood 1. 2. 3. Remove outer mesh filters of range hood. Attach damper to rectangular cutout on top of the range hood using the screws provided (Figure 2).
BX212/BX215 INSTALLATION - INSTALLATION CUTOUT TEMPLATES BX21228/BX21528 BX21234/BX21534 16 Cyclone Insert Installation - English
BX600/CLX60 INSTALLATION - PARTS SUPPLIED 1 × Hood PRE-INSTALLED 1 × Round Adapter PRE-INSTALLED 2 × LED Lights (1.
BX600/CLX60 INSERT HOOD INSTALLATION This appliance requires 120V 60Hz electrical supply and connection to an individual properly grounded branch circuit protected by a circuit breaker or time delay fuse. Install the BX600/CLX60 Range Hood 1. CAUTION • Remove outer baffle filters of range hood (Figure 1). Figure 1. At least two installers are required due to the weight and size of the hood. WARNING • • Turn off power circuit at the service panel before wiring this unit.
BX600/CLX60 INSTALLATION - INSTALLATION CUTOUT TEMPLATES BX600/CLX6028 13 ¼” BX600/CLX6034 32” Cyclone Insert Installation - English 19
INSERT HOODS SPECIFICATIONS BX2000/BX2010 BX212/BX215 BX600/CLX60 SS13024/SS13030 SIZE 28” BX215-28”/34” BX212-22"/28" 28”/34” 24”/30” MAX. CUBIC FEET/METER (CFM) 680 550 600 550 MAX.
TROUBLESHOOTING ISSUE CAUSE Unit doesn’t work after 1. installation. 1. Ensure power is ON for the circuit breaker and unit. 2. The power line and the cable locking connector 2. are not connected properly. Check the power connection with the unit is connected properly. 3. The unit does not turn on when it is at full extension (SS130 only). 3. Check if the slide control is turned off or set to 0. Light indicates power 1. ON but motor doesn’t turn. 2. The motor is defective, possibly seized. 1.
MAINTENANCE For a complete description of our maintenance and operating instructions you may visit us online at www.CycloneRangeHoods.com to download your model’s Use and Care Guide. Due to the fact that we are always striving to improve our products and take advantage of advances in technology there may be slight variations in your product. WARNING • Always switch off power and unplug before cleaning and maintenance.
CONTROL PANEL Model: BX212/BX215 The unit is controlled by slide controls. The fan and light are each controlled by a slide control. The fan switch has four positions: HIGH, MED, LOW and OFF. The light switch has two positions, ON and OFF. Model: SS130 The unit is controlled by slide controls. The fan and light are each controlled by a slide control. The fan switch has four positions: HIGH, MED, LOW and OFF. The light switch has two positions, ON and OFF.
CYCLONE RANGE HOODS LIMITED WARRANTY Cyclone Range Hoods Inc. (hereunder called “The Company”) provides a warranty that its products are free from defects in workmanship and materials for a period of two (2) years from the date of purchase. This warranty includes in-home service (where applicable) for the first year and workshop service for the second year. During that time period, The Company will, at the Company’s option, repair or replace without charge any parts or complete unit found to be defective.