Specifications
2
CYCLONE 866F OWNER’S GUIDE
Technical Specifications
Operating Voltage:
Current Consumption:
Int. Batt. Charge Time:
Int. Batt. Alarm Time:
LED Flashing (Armed):
Operating Temp.:
Siren Blast Volume:
Siren Chirp Volume:
Alarm Unit
Transmitter
TRANSMITTER NOTES:
• Even though the transmitter is waterproof, it is not advised to swim or
surf or dive with the transmitter, or press buttons underwater. If water
does get inside, immediately remove the batteries and allow to thor-
oughly dry out for 24 hours.
• Avoid leaving in direct sunlight for extended periods, and avoid leav-
ing near sources of intense heat.
• There are no screws used to hold the case together. To open, you may use
aatheadscrewdriver,butnotethatexcessiveforcemaydenttheplastic.
12Vdc (8v min.; 15v max.)
Armed = 4mA; Disarmed = 3mA;
Full Siren Blast = 270mA; SLEEP = 1mA (Immob. Off)
Approx. 3 hours (continuous charging)
2 hours (battery used only when 12v line is cut)
1 ash every 2 sec.
(LED is off when Disarmed/SLEEP)
-20°C to +60°C
(limited by specications of int. batt.)
120dB @ 30cm/1ft. (105dB when driven by int. batt.)
110dB @ 30cm/1ft. (“Soft Chirp”)
RF Output:
Digital Code:
Batteries:
Transmit Range:
Batt. Life:
Housing:
Xtal-controlled 303.875MHz (SAW lter) @ 6,500µV/m
66-bit Rolling Code (anti code grabbing)
Two CR1616, 3V Lithium cells
15m / 50ft. (typical in-city use)
1 year avg. @ 6 presses per day
Waterproof (can be submerged)
Status LED
Housing:
Light Color:
Waterproof (intended for outside-bike use)
Blue