User`s guide
Configuration>Serial/AUX>Physical Ports>Power Management
248
AlterPath OnSite Administrator’s and User’s Guide
Note: The checkbox next to “Enable IPMI on this port” cannot be checked
unless an OnSite administrator has previously configured an IPMI server as
described under Access>IPMI Power Mgmt.
Figure 6-33:Web Manager Configuration>Serial/AUX>Physical
Ports>Power Management Options
If only “Enable Power Management on this port” is selected, the “IPMI key”
and “IPMI Server” menu do not appear. If only “Enable IPMI on this port” is
checked, only the “IPMI key” and “IPMI Server” menu appear.
Power management while connected to a port is possible only when one or
both of the following conditions are true
• IPDU power management can be configured when the device connected
to this serial port is plugged into one or more outlets on an AlterPath PM
IPDU that is connected to an AUX port on the OnSite, and the AUX port
is configured for power management.
See “To Configure an AUX Port for IPDU Power Management [Expert]”
on page 266.