User`s guide

Configuration>KVM>General>IP Users
224
AlterPath OnSite Administrators and Users Guide
When you select a port and click the “Modify” button, the dialog box shown
in the following figure appears.
Figure 6-24:KVM “Modify Port” Dialog Box
On the Modify Port dialog box, the administrative user can do the following:
Configure an alias for a single KVM port
Configure power management for the server that is connected to the KVM
port while the user is logged into the server
Power management while connected to a KVM port is possible only when the
following conditions are true:
The device connected to this port is plugged into an AlterPath PM IPDU
that is connected to the AUX1 port on the OnSite
The AUX1 port is configured for power management.
See “To Configure an AUX Port for IPDU Power Management [Expert]”
on page 266.
You know the outlet number or numbers into which the servers power
cable or cables are plugged.