System information
Introduction 55
Tasks for Configuring IP Addresses
Tasks for Configuring IP Addresses
See “OnBoard-specific Tasks for Configuring New Devices” on page 346.
Example and Demo Scripts and Application
Notes
The following helps are available for OnBoard administrators:
• Configuration example scripts in /libexec/example_scripts
• Demo scripts in/libexec/demo_scripts
• Application notes in /usr/share/docs/OnBoard/
Application_Notes with future updates to be posted at http://
www.cyclades.com/support/downloads.php under the
product name “AlterPath OnBoard.”
Data Buffering on the OnBoard
When data buffering is configured, data is stored in logs under /var/log/
console/devicename.log. The logs are rotated frequently so that the
storage capacity of the OnBoard flash memory is not exceeded.
An OnBoard administrator can configure a default for buffering of data from
device console sessions and then configure each device to use the default or
not
. The administrator may also manually modify the /etc/
conserver.cf
file to change the variable LOGDIR=/var/log/
console
to point to another data storage location. Administrators can set
up storage either in local files on the OnBoard’s resident flash memory, on the
hard disk of an external server, or on a PCMCIA flash memory card.
An administrator can configure data buffering either by using the Web
Manager or by using the cycli utility as described in the following sections:
• “Configuring Devices” on page 197
• “onboard global default databuf” on page 333
• “onboard server” on page 334