System information

Device Configuration
46 AlterPath OnBoard Administrator’s Guide
See “Configuring Sensor Alarms” on page 233 for how to configure sensor
alarms through the Web Manager. See “sensoralarm” on page 336 for cycli
command instructions.
Device Configuration
When connecting devices to the OnBoard, observe the following
recommendations, which are illustrated in Figure 1-1:
Connect the main Ethernet port(s) on connected servers or devices to a
production network, which must be accessible to all those who need to
access the device.
Connect the dedicated Ethernet port on each service processor or device
to one of the OnBoard’s private Ethernet ports. The connections between
the OnBoard and devices make up the management network.
Condition
Trigger when value is >INSIDE< range
Trigger when value is <OUTSIDE> range
Trigger when value CHANGES
Range
Applies to the INSIDE and OUTSIDE conditions. The low and
high thresholds can be any numeric value, including floats. For
example, for a fan whose average reading is 1470 RPR, you
might want to specify a low threshold of 1000 and a high
threshold of 1600.
Interval
A polling interval chosen by the administrator: a time in minutes
or hours
Action
Syslog message trap
Pager
•Email
Comment
Any desired comment to identify the source of the alarm
Table 1-23: Values for Configuring Sensor Alarms (Continued)
Values Description