Installation guide

Installation 33
6.Enabling Access to the Web Manager
1. Using either a terminal or a terminal emulation program installed on a
computer that is connected to the OnBoard, start a session with the
following console port settings:
2. Log into the console port as root.
The default password is “cyclades.”
Caution: For security, it is essential for root to change the root password.
3. Enter the passwd command, and enter and confirm a new password
when prompted.
4. Invoke the cycli utility.
5. Make sure the primary Ethernet interface (eth0) is active.
Note: Alternately, you can enter all the set network interface
eth0 parameters in Step 5 through Step 10 in a single cycli
command line.
Table 2-4: Terminal Session Settings for Console Port Access
Serial Speed: 9600 bps Parity: None Flow Control: None
Data Length: 8 bits Stop Bits: 1 ANSI emulation
OnBoard login: root
Password: cyclades
[root@OnBoard /root]#
[root@OnBoard /root]# passwd
[root@OnBoard /root]# cycli
cli>
cli> set network interface eth0 active yes