Service manual
Chapter 7 Upgrades and Troubleshooting 74
Cyclades-TS
Installation & Service Manual
Using a different speed for the serial console
The serial console is originally configured to work at 9600 bps. If the customer wants to change that, it is
necessary to run bootconf. The user will be presented with the screen:
Current configuration
MAC address assigned to Ethernet [00:60:2e:00:16:b9]
IP address assigned to Ethernet interface [192.168.160.10]
Watchdog timer ((A)ctive or (I)nactive) [A]
Firmware boot from ((F)lash or (N)etwork) [F]
Boot type ((B)ootp,(T)ftp or Bot(H)) [T]
Boot File Name [zvmppcts.bin]
Server's IP address [192.168.160.1]
Console speed [9600]
(P)erform or (S)kip Flash test [P]
(S)kip, (Q)uick or (F)ull RAM test [F]
Fast Ethernet ((A)uto Neg, (1)00 BtH, 100 Bt(F), 10 B(t)F, 10 Bt(H)) [A]
Fast Ethernet Maximun Interrupt Events [0]
Type <Enter> for all fields but the Console Speed. When presented the following line:
Do you confirm these changes in flash ( (Y)es, (N)o (Q)uit ) [N] :
Enter Y and the changes will be saved in flash. Reboot the unit to have the changes effective and use the
console at the new speed.