Chapter 6 Configuration 48
Cyclades-TS Installation & Service Manual
2. From the console, ping 200.200.200.3 to make sure the server is reachable.
3. Make sure that the physical connection between the Cyclades-TS and the terminals is correct. A cross cable
(not the modem cable provided with the product) should be used. Please see the hardware specifications
appendix for pin-out diagrams.
4. The Cyclades-TS has been set for communication at 9600 bps, 8N1. The terminals must also be configured
with the same parameters.
5. From a terminal connected to the Cyclades-TS, try to log in to the server using the username and password
configured in item one.
Now continue on to step four later in this chapter.
STEP THREE - REMOTE ACCESS SERVER
The remote access server profile allows a modem user to access the LAN. Radius authentication is used in this
example and ppp is chosen as the protocol.
WARNING! Remote Access Server functionality was only added to provide a secure and effective
means of out-of-band access to servers attached to our product. Use exclusively as a Remote Access
Server is not advised.