Service manual
Appendix F Configuration Wizard 150
Cyclades-TS Installation & Service Manual
Parameter Value Comments
idletimeout 0 Don’t finish the session by idle timeout.
data_buffering
0
Data buffering disabled.
DB_timestamp
0
Don’t include time in the data buffering.
alarm
0
Don’t generate alarm syslogs.
syslog_buffering 0 Don’t generate syslogs for data buffering.
dont_show_DB_
menu
1
Don’t show DB menu when the session is opened.
break_sequence "break. this sequence will generate a BREAK in
the serial port, in an SSH session.
sniff_mode
out
Only output packets can be traced.
admin_users peter, john If the sniff must be disabled and these users don't exist, this
value can be kept.
multiple_sessions
no
Don’t accept multiple sessions for sniff.
escape_char ^z This character will cause a sniff session to switch to the command
mode.
serverfarm Server_connected
serial<port_number>
Name of the SSH server connected to the serial port
TS profile:
Parameter Value Comments
speed
9600
Port speed - 9600 bps.
datasize 8 8 bits.
stopbits 1 1 stop bit.
parity None No parity
flow hard Hardware flow control.
dcd 1 Sensitive to DCD signal.
sysutmp 1 Write the users in utmp log file.
syswtmp 0 Don't write the users in wtmp log file.