Installation manual

Chapter 4 Configuration 38
Cyclades-TS Installation Manual
Parameter Description Value for This Example
s35.tty See s33.tty. 20.20.20.2:7035
s35.serverfarm An alias for this port. Server_on_slave1_serial_s3
s35.ipno See s33.ipno. 0.0.0.0
etc. for s36-s64
S65.tty The format of this parameter is
IP_of_Slave[:slave_socket_port] for non-master ports.
The value 7301 was chosen arbitrarily for this example.
20.20.20.3:7301
S65.serverfarm An alias for this port. Server_on_slave2_serial_s1
S65.ipno See s33.ipno. 0.0.0.0
S66.tty See s65.tty. 20.20.20.3:7302
S66.serverfarm An alias for this port. Server_on_slave2_serial_s2
S66.ipno See s33.ipno. 0.0.0.0
S67.tty See s65.tty. 20.20.20.3:7303
S67.serverfarm An alias for this port. Server_on_slave2_serial_s3
S67.ipno See s33.ipno. 0.0.0.0
etc. for s68-s96
FIGURE 4.15 MASTER CYCLADES-TS CONFIGURATION (CONT.)
The Slave Cyclades-TSs do not need to know they are being accessed through the Master Cyclades-TS. Their
port numbers, however, must agree with those assigned by the Master.
Parameter Value for This Example
all.protocol socket_server
all.authtype none
conf.eth_ip 20.20.20.2
all.socket_port 7033+
FIGURE 4.16 CYCLADES-TS CONFIGURATION FOR SLAVE 1 (WHERE IT DIFFERS FROM THE
STANDARD CAS PROFILE)