Service manual

Cybex Arc Trainer 610A Service Manual
Service
Page 4-39
B. Locate the new contact heart rate cables connected
to the lower display cable. The right side cables are
located in the outermost locations in the lower display
cable connector. See Figure 32.
C. Tape the new pairs of contact heart rate wires to the
old wires cut in step 6A. See Figure 33. NOTE: One
brown wire and one black wire make a pair.
D. Locate the new cable’s 10 pin connector end of the
lower display cable.
E. Tape the new 10 pin connector to the old lower
display cable. NOTE: Be sure to tape the correct ends
together. See Figure 33.
F. Using a flat head screwdriver pry the contact
heart rate cable plug out of the frame. See
Figure 23.
G. Gently pull all three cables through the frame
tubes. See Figure 34. NOTE: Stop pulling
when the new cables exit the frame tubes.
H. Remove the tape and discard the old cable.
I. Confirm that the cable is routed through the
access holes (see Figure 30) and through the
wire holder bracket (see Figure 35).
J. Connect the display cable to the lower control
board.
K. Connect the contact heart rate cables to the
cable plugs removed in step 6F.
L. Plug the two contact heart rate cable sockets into the frame.
7. Attach the console.
A. Place the console assembly in position and connect the upper display cable to the lower
display cable. See Figure 29.
B. Using an Allen wrench, attach the four screws and four lock washers securing the console
assembly in place.
8. Secure the cable.
A. Check to see that all of the connectors are connected firmly in their proper place.
B. Place the lower board shield in position and snap it in.
9. Attach the access cover.
A. While being sure not to pinch any cables, place the access cover in position.
B. Using a Phillips head screwdriver, attach the four screws removed in step 2A.
Figure 32
Right Side
Heart Rate
Wires
Left Side
Heart Rate
Wires
Figure 33
Left Contact
Heart Rate
Cables
Right Contact
Heart Rate
Cables
Display
Cables