Service manual

26
4 / RETRO-KIT INSTALLATION
NOTE: When starting a test stepping may help prevent battery
drainage. You can enter the tests without stepping first.
However, do not step while entering Static Diagnostic Check.
Error 3
After installing this kit an initialization sequence is required. This will
be noted by ERR 3 appearing on the display when START is first
pressed. Follow the steps below to enter an initialization sequence.
1. Start stepping and press START.
2. Note ERR 3.
3. Press the + and - buttons in the DURATION window and
hold until repeated beep is heard.
4. Press the + and - keys in the INTENSITY window to exit the
diagnostic mode.
5. Wait for countdown to complete.
Replace Calibration Settings
After installing the new board, replace calibration settings with the
recorded values.
1. Start stepping and press START.
2. Press the + and - keys in the INTENSITY window (at the
same time).
3. Press CARDIO 1 and use the right + or - key to adjust the
first (smaller) number recorded earlier.
4. Press START and use the right + or - key to adjust the
second (larger) number recorded earlier.
5. Press START and "SAVE" will appear in the right window.
6. Press the + and - keys in the INTENSITY window to exit the
diagnostic mode.
Pulley Replacement
NOTE: It is not necessary to remove the shroud.
NOTE: Wear safety glasses during this procedure.
To release tension from linkage system:
1. Position yourself straddling the side frame tube as shown in
See figure 5-1. Using your foot push the foot pedal
backwards until you can rotate the long tie rod assembly
freely with your hand.
2. Hold the foot pedal in this position and remove the 1/2-13 x
1.50" screw using a 5/16" Allen wrench.
3. Lower the long tie rod assembly to the floor.
4. Slowly and carefully let the foot pedal come forward until
Do not use any lubricant on
tie rod ends. Using lubricant
on tie rod ends can destroy
bearings and will void
warranty.
CAUTION
Fig. 5-1