® Panel PCs FPC 1502 Series NEMA 4 Sealed 15" Panel PC System; 2 PCI Expansion Slots FPC 1502-C20/-T: Celeron 2.0GHz/Optional Touchscreen FPC 1502-P24/-T: Pentium 2.4GHz/Optional Touchscreen FPC 1502-P30/-T: Pentium 3.06GHz/Optional Touchscreen USER’S MANUAL VER. 1.0 • 2004 No part of this manual may be reproduced without permission CyberResearch , Inc. ® www.cyberresearch.com 25 Business Park Dr.
® CyberResearch Panel PCs FPC 1502 Series ©Copyright 2004 All Rights Reserved. 2004 The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of CyberResearch, Inc. In no event will CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Intentionally Blank iv ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Packing List Before you begin installing your card, please make sure that the following materials have been shipped: • 1 FPC 1502 Series Panel PC • 10 Panel mount clip & screw • 1 Hardware Bag • 1 Waterproof Gasket • 1 Jumper Cap • 2 Easy stand • 1 Power Cord (optional) • 1 CD-ROM for manual (in PDF format) and drivers If any of these items should be missing or damaged, please contact your distributor or sales representative immediately.
® CyberResearch Panel PCs FPC 1502 Series Safety 1. Read these safety instructions carefully. 2. Keep this user's manual for later reference. 3. Disconnect this equipment from any AC outlet before cleaning. Do not use liquid or spray detergents for cleaning. Use a damp cloth. 4. For pluggable equipment, the power outlet must be installed near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation.
® CyberResearch Panel PCs FPC 1502 Series c. The equipment has been exposed to moisture. d. The equipment does not work well, or you cannot get it to work according to the users manual. e. The equipment has been dropped and damaged. f. The equipment has obvious signs of breakage. 15. DO NOT LEAVE THIS EQUIPMENT IN AN UNCONTROLLED ENVIRONMENT WHERE THE STORAGE TEMPERATURE IS BELOW -20° C (-4° F) OR ABOVE 60° C (140° F). IT MAY DAMAGE THE EQUIPMENT. 16.
® CyberResearch Panel PCs FPC 1502 Series FCC Safety This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. viii ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Table of Contents Packing List ....................................................................v Safety..............................................................................vi FCC Safety......................................................................viii General Information ................... ..1 Introduc tion................................................................... 3 Features .........................................................
CPEM Series ® CyberResearch CPU Cards Fan Connector (CN8&CN24).......................................22 10/100Base-Tx Ethernet Connector (CN11) ................22 Option PME Connector (CN12) ...................................22 Floppy Connector (CN13) ............................................23 LPT Port Connector (CN14).........................................23 COM1~3 RS-232/422/485 Serial Port Connector (CN16) ......................................................................................
® CyberResearch CPU Cards CPEM Series Power management Setup .............................................48 PnP/PCI configuration..................................................49 PC Health Status ...........................................................50 Frequency/Voltage control............................................51 Load FPC 1502 Defaults...............................................52 Set Supervisor/User Password ......................................53 Save & Exit Setup ...............
1 Chapter General Information
® CyberResearch Panel PCs FPC 1502 Series Introduction FPC 1502 Series is the first Pentium®4 industrial board in the CyberResearch Panel PC product line. It features a PGA478 socket that can accommodate Pentium®4 3.06GHz and Celeron® processors, supporting FSB speed of up to 400/533MHz. Best performance for multimedia solution The FPC 1502 Series also supports DDR DRAM up to 1GB, 4X AGP, and 5.1 channels audio output. It can provide the strong multimedia functions.
FPC 1502 Series ® CyberResearch Panel PCs performance application. Most of all Pentium®4 Level processors are suitable for FPC 1502 Series. 4 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Features 15” TFT XGA (1024 x 768) LCD All-in-one SBC support Socket 478 based Intel® Pentium®4 Processor Support Intel®Hyper-Threading Technology Anti-vibration disk drive bay for HDD Water-proof and anti-scratch aluminum front panel with USB port IP-65 certification Two free PCI expansion slots Digital I/O (8 in, 8 out as Default, up to 16 in or 16 out) Resistive Touch screen (Optional) CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Specifications System Construction Heavy-duty steel chassis & IP-65 certified aluminum front panel CPU Socket 478 based Pentium® 4(.13μ) / Celeron® Processors up to 3.
® CyberResearch Panel PCs FPC 1502 Series RS-232/422/485 (COM 4 is reserved for touch screen) 1 parallel port (supports ECP/EPP) 1 PS/2 mouse and keyboard port 1 VGA port Mic in, Line in, Line out, S/P DIF 5.1 channels audio port GPIO: 16 in or 16 out Storage Disk Drive Anti-vibration 2.5”HDD, Slim FDD and Slim CD-ROM USB ports 4 USB 2.0 ports on rear chassis 1 USB 2.
® CyberResearch Panel PCs FPC 1502 Series 75/100mm holes Expansion slots 2 PCI slots 1 Mini PCI socket 6in1 card reader. Because of drivers bug, after successfully installing card reader drivers, two vanity disk drives appear: XD and Flash. Please ignore the two useless disk drives.
® CyberResearch Panel PCs FPC 1502 Series Power Supply AC input 250W (standard offer): Output rating: 250W Input voltage: 100VAC~240VAC@47~63Hz Output voltage: +3.3V@16A, + 5V@25A, +12V@13A, +5VSB@2A, -5V@0.3A, -12V@0.8A 24V DC input: Output rating: 300W (Maximum) Input voltage: 19VDC~36VDC@30A Maximum Output voltage: +5V@25A, +12V@22A, +3.3V@20A, -5V@0.8A, -12V@1A, 5VSB@1.5A CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 9 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series LCD Specifications Display type 15” color TFT LCD Max. Resolution 1024 x 768 Max. Colors 256K Dot size (mm) 0.297 x 0.
® CyberResearch Panel PCs FPC 1502 Series Vibration 1G / 5~500Hz (Random / operation) Shock 15G peak acceleration (11 msec. duration) / operation EMC CyberResearch, Inc. 25 Business Park Drive Branford, CT USA CE/FCC Class B 11 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series Dimensions 402.2 FPC 1502 Series Unit:mm 296.0 43.0 144.0 20.0 336.0 20.0 444.0 Cutout Size:405*299 mm 12 ©Copyright 2004 CyberResearch, Inc.
2 Chapter Hardware Installation
® CyberResearch Panel PCs FPC 1502 Series Safety Precautions Always completely disconnect the power cord from your board whenever you are working on it. Do not make connections while the power is on, because a sudden rush of power can damage sensitive electronic components. Always ground yourself to remove any static charge before touching the board. Modern electronic devices are very sensitive to static electric charges. Use a grounding wrist strap at all times.
® CyberResearch Panel PCs FPC 1502 Series Location of Connectors and Jumpers Component Side CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 15 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series List of Jumpers There are a number of jumpers in the board that allow you to configure your system to suit your application. The table below shows the function of each jumper in the board: Jumpers 16 Label Function JP1 Clear CMOS JP2 Audio Out Select JP3 COM2 Ring/+5V/+12V Selection JP4 COM2 RS-232/422/485 Selection JP5 COM2 RS-232/422/485 Selection JP6 ATX Power simulate AT Power JP7 LCD Voltage Selection ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series List of Connectors There are a number of connectors in the board that allow you to configure your system to suit your application.
® CyberResearch Panel PCs FPC 1502 Series Setting Jumpers You configure your card to match the needs of your application by setting jumpers. A jumper is the simplest kind of electric switch. It consists of two metal pins and a small metal clip (often protected by a plastic cover) that slides over the pins to connect them. To “close” a jumper you connect the pins with the clip. To “open” a jumper you remove the clip. Sometimes a jumper will have three pins, labeled 1, 2 and 3.
® CyberResearch Panel PCs FPC 1502 Series Clear CMOS (JP1) Warning: To avoid damaging the computer, always turn off the power supply before setting “ Clear CMOS. ” Before turning on the power supply, set the jumper back to “Normal.” JP1 Function 1-2 Active (Default) 2-3 Clear Audio Out Select (JP2) JP2 Function 1-3, 2-4 W/O Amplifier (Default) 3-5, 4-6 W/ Amplifier COM2 Ring/+5V/+12V Selection (JP3) JP3 Function 1-2 +12V 3-4 +5V 5-6 Ring (Default) CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series COM2 RS-232/422/485 Select (JP4&JP5) JP4 JP5 Function 1-2, 4-5, 7-8, 10-11 1-2 RS-232 (Default) 2-3, 5-6, 8-9, 11-12 3-4 RS-422 2-3, 5-6, 8-9, 11-12 5-6 RS-485 ATX Power simulate AT Power (JP6) 20 JP6 Function 1-2 ON ATX Power Simulate AT Power 1-2 OFF ATX Standard (Default) ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series IDE Connector (CN1) Pin Signal Pin Signal 1 IDE RESET 2 GND 3 DATA7 4 DATA8 5 DATA6 6 DATA9 7 DATA5 8 DATA10 9 DATA4 10 DATA11 11 DATA3 12 DATA12 13 DATA2 14 DATA13 15 DATA1 16 DATA14 17 DATA0 18 DATA15 19 GND 20 N.C 21 REQ 22 GND 23 IO WRITE 24 GND 25 IO READ 26 GND 27 IO READY 28 GND 29 DACK 30 GND 31 IRQ14 32 N.
® CyberResearch Panel PCs FPC 1502 Series Fan Connector (CN8&CN24) Pin Signal 1 GND 2 +5V 3 FAN SPEED SENSE 10/100Base-Tx Ethernet Connector (CN11) Pin Signal Pin Signal 1 TX+ 9 N.C 2 TX- 10 N.C 3 RX+ 11 GND 4 N.C 12 GND 5 N.C 13 N.C 6 RX- 14 N.C 7 N.C 15 N.C 8 N.C 16 N.C Option PME Connector (CN12) 22 Pin Signal Pin Signal 1 +5VSB 2 GND 3 #PME 4 SMB_DATA 5 SMB_CLK ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Floppy Connector (CN13) Pin Signal Pin Signal 1 GND 2 REDWC 3 GND 4 N.
® CyberResearch Panel PCs FPC 1502 Series 5 PTD1 6 INIT 7 PTD2 8 SLIN 9 PTD3 10 GND 11 PTD4 12 GND 13 PTD5 14 GND 15 PTD6 16 GND 17 PTD7 18 GND 19 ACK 20 GND 21 BUSY 22 GND 23 PE 24 GND 25 SELECT 26 N.C COM1~3 RS-232/422/485 Serial Port Connector (CN16) Only COM1 support “Wake on Ring” function. 24 Pin Signal Pin Signal 1 DCD1 2 DSR1 3 RXD1 4 RTS1 5 TXD1 6 CTS1 7 DTR1 8 RI1 9 GND 10 N.
® CyberResearch Panel PCs FPC 1502 Series 23 RXD3 24 RTS3 25 TXD3 26 CTS3 27 DTR3 28 RI3 29 GND 30 N.C 31 DCD4 32 DSR4 33 RXD4 34 RTS4 35 TXD4 36 CTS4 37 DTR4 38 RI4 39 GND 40 N.C PS2 Keyboard/Mouse Connector (CN17) Pin Signal 1 KB_DATA 2 KB_CLK 3 GND 4 +5V 5 MS_DATA 6 MS_CLK CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 25 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series Digital I/O Port 26 Pin Signal I/O Address Setting 1 Digital-IN / OUT 841H 2 Digital-IN / OUT 841H 3 Digital-IN / OUT 841H 4 Digital-IN / OUT 841H 5 GND 6 GND 7 Digital-IN / OUT 841H 8 Digital-IN / OUT 841H 9 Digital-IN / OUT 841H 10 Digital-IN / OUT 841H 11 GND 12 GND 13 Digital-IN / OUT 801H 14 Digital-IN / OUT 801H 15 Digital-IN / OUT 801H 16 Digital-IN / OUT 801H 17 GND 18 GND 19 Digital-IN / OUT 801H 20
® CyberResearch Panel PCs FPC 1502 Series The pin definitions and registers mapping are illustrated below: Address: 841H 4 in / 4 out Pin1 Pin2 Pin3 Pin4 Pin7 Pin8 Pin9 Pin10 GPI 27 GPI 26 GPI 25 GPI 24 GPO 23 GPO 22 GPO 21 GPO 20 MSB LSB 8 in Pi n 1 Pin2 Pin3 Pin4 Pin7 Pin8 Pin9 Pin10 GPI 27 GPI 26 GPI 25 GPI 24 GPI 23 GPI 22 GPI 21 GPI 20 MSB LSB 8 out Pin1 Pin2 Pin3 Pin4 Pin7 Pin8 Pin9 Pin10 GPO 27 GPO 26 GPO 25 GPO 24 GPO 23 GPO 22 GPO 21 GPO 20 MSB
® CyberResearch Panel PCs FPC 1502 Series 8 out Pin13 Pin14 Pin15 Pin16 Pin19 Pin20 Pin21 Pin22 GPI 27 GPI 26 GPI 25 GPI 24 GPI 23 GPI 22 GPI 21 GPI 20 MSB LSB VGA Display Connector (CN22) Pin Signal Pin Signal 1 Red 9 GND 2 VCC 10 HSYNC 3 Green 11 GND 4 GND 12 VSYNC 5 Blue 13 GND 6 N.C 14 SCL 7 N.C 15 GND 8 SDA 16 N.C ATX Power Connector (CN27) 28 Pin Signal Pin Signal 1 +3.3V 11 +3.3V 2 +3.
® CyberResearch Panel PCs FPC 1502 Series 7 GND 17 GND 8 POWER OK 18 -5V 9 +5VSB 19 +5V 10 +12V 20 +5V ATX Power 12V Connector (CN28) Pin Signal Pin Signal 1 GND 2 GND 3 +12V 4 +12V CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 29 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs FDD & CD-ROM Installation We will guide you how to lock FDD and CD-ROM together. Please see the detail as follows. Step 1: Plug in FDD cable 30 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Step 2: Fasten the FDD and CD-ROM together with two brack ets on the both sides symmetrically. Step 3: Fasten the transferring bar with a pair of screws on the back of the CD-ROM. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 31 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs Step 4: Plug in CD-ROM Cable 32 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series HDD Installation In the following, we will guide you how to install HDD. Make sure that all parts are provided before you start the installation. Step 1: Lock with the screws as the illustration shown. Step 2: Cover the screws with four pieces of anti-vibration rubbers CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 33 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs Step 3: There’ re two pieces of iron surfaces as the illustration shown. Step 4: Locate the HDD on one piece of the iron surface and fasten it with the screws. 34 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Step 5: Cover it with another piece of iron surface and lock it with the screws. Step 6: Fix the HDD module into the FPC 1502 Series chassis and plug the cable in. Fix the HDD module with the screws Plug the cable in CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 35 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series Easy Stand Installation Two L-shaped easy stands accompany the product. Refer to the following illustration to install them. 1. Affix the L-shaped easy stands with the screws on both sides of the monitor. See the illustration below: *4-M4 Screw 36 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Panel Mount Kit Installation Some screw sets will come with the product for user to mount the monitor on the wall. See the steps below along with the illustration. Step 1: Bore the screw into the screw nut. Step 2: Locate the s crew set into the hole around the monitor as the right illustration and pull it back to lock the screw set on the hole. Step 3: Turn the screw around to make it tight until it is closed to the wall.
® CyberResearch Panel PCs FPC 1502 Series Waterproof Gasket Installation The following illustration shows you how to install the waterproof gasket behind the monitor set. 1. Install the gasket behind the monitor set. 2. Install the monitor set on the wall. Gasket Wall 38 ©Copyright 2004 CyberResearch, Inc.
3 Chapter BIOS Installation
® CyberResearch Panel PCs FPC 1502 Series System test and initialization These routines test and initialize board hardware. If the routines encounter an error during the tests, you will either hear a few short beeps or see an erro r message on the screen. There are two kinds of errors: fatal and nonfatal. The system can usually continue the boot up sequence with non-fatal errors.
® CyberResearch Panel PCs FPC 1502 Series information has been erased. The FPC 1502 Series CMOS memory has an integral lithium battery backup for data retention. However, you will need to replace the co mplete unit when it finally runs down. Award BIOS Setup Awards BIOS ROM has a built-in Setup program that allows users to modify the basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it retains the Setup information when the power is turned off.
FPC 1502 Series ® CyberResearch Panel PCs Standard CMOS Features Use this menu for basic system configuration. (Date, time, IDE, etc.) Advanced BIOS Features Use this menu to set the advanced features available on your system. Advanced Chipset Features Use this menu to change the values in the chipset registers and optimize your system performance. Integrated Peripherals Use this menu to specify your settings for integrated peripherals. (Primary slave, secondary slave, keyboard, mouse etc.
® CyberResearch Panel PCs FPC 1502 Series Set Supervisor/User Password Use this menu to set Supervisor/User Passwords. Save and Exit Setup Save CMOS value changes to CMOS and exit setup. Exit Without Saving Abandon all CMOS value changes and exit setup. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 43 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs Standard CMOS Features When you choose the Standard CMOS Features option from the INITIAL SETUP SCREEN menu, the screen shown below is displayed. This standard Setup Menu allows users to configure system components such as date, time, hard disk drive, floppy drive and display. Once a field is highlighted, on-line help information is displayed in the right box of the Menu screen. 44 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Advanced BIOS Features By choosing the Advanced BIOS Features option from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 45 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series Advanced Chipset Features By choosing the Advanced Chipset Features option from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. Attention: The LCD signal may be turned off automatically after the VGA driver is installed, please press “Ctrl + Alt + F3” to enable LCD signal again. 46 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Integrated Peripherals By choosing the Integrated Peripherals from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 47 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs Power management Setup By choosing the Power Management Setup from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. 48 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series PnP/PCI configuration By choosing the PnP/PCI configurations from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 49 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs PC Health Status By choosing the PC Health Status from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. 50 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Frequency/Voltage control By choosing the Frequency/Voltage Control from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values for the FPC 1502 Series. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 51 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
FPC 1502 Series ® CyberResearch Panel PCs Load FPC 1502 Series Defaults When you press on this item you get a confirmation dialog box with a message similar to: To load the FPC 1502 defaults, select Load APC-8152 Defaults. Selecting "Y" loads the BIOS default values for the most stable, minimal performance system operations. 52 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Set Supervisor/User Password You can set either SUPERVISOR or USER PASSWORD, or both of them. The difference between the two is that the supervisor password allows unrestricted access to enter and change the options of the setup menus, while the user password only allows entry to the program, but not modify options. To abort the process at any time, press Esc.
FPC 1502 Series ® CyberResearch Panel PCs Save & Exit Setup If you select this option and press , the values entered in the setup utilities will be recorded in the chipset’ s CMOS memory. The microprocessor will check this every time you turn on your system and compare this to what it finds as it checks the system. This record is required for the system to operate. 54 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Exit without saving Selecting this option and pressing allows you to exit the Setup program without recording any new value or changing old one. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 55 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch Panel PCs FPC 1502 Series Limitations 56 1. Due to Intel chipset limitation, when CMOS was set up to “LCD + CRT”, the LCD display will not support full-screen appearance. 2. Because of USB chipset limitation, front USB port and Card reader USB interface are linked together, when user “disable” front USB port ( USB Port 3 controller), the card reader must be forced to disable at same time. ©Copyright 2004 CyberResearch, Inc.
4 Chapter Driver Installation
® CyberResearch Panel PCs FPC 1502 Series There are several installation ways depending on the driver package under different Operating System application. Please follow the sequence below to install the drivers: Step 1 – Install Intel INF Update For Windows 9x-XP Driver Step 2 – Install Intel 845G Graphic Driver Step 3 – Install Intel Application Accelerator for Windows 9x-XP Driver Step 4 – Install Intel LAN Driver V6.
® CyberResearch Panel PCs FPC 1502 Series system will ask you to reboot the computer. During the installation process, it will appear the pop up window as following. 2. 3. Please press ok and it will appear the pop up window as following. 4. Please change the path to the installation folder and search for the two files named as ikch8xx.cat and isb8xx.cat. A driver installation screen will appear, please follow the onscreen instructions to install the driver in sequence and click on the Next button.
® CyberResearch Panel PCs FPC 1502 Series Windows 98 CD ROM and key in its path. Then click on the OK button to key in path. 3. Click on the Finish button to finish installation process. And allow the system to reboot. 4. The LCD signal may be turned off automatically after the VGA driver is installed, please press "Ctrl+Alt+F3" to enable LCD signal again. LAN Driver Installation We strongly recommend that you shall not install LAN driver by clicking on Autorun Exe.
® CyberResearch Panel PCs FPC 1502 Series Card Reader Driver Installation 1. Enter Driver → System → FPC 1502 & FPC 1702 Series → Step 6 Card Readers Driver folder. 2. Double click on the Setup exe. file. 3. Language setting: Choose the highlighted item below to operate your system in English. 4. Follow the instruction that the window will show to finish the installation. Touch screen Driver Installation 1. Enter Driver → System → FPC 1502 & FPC 1702 Series → Step 7 Touch screen Driver folder.
® CyberResearch Panel PCs FPC 1502 Series Intentionally Blank 66 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Product Service Diagnosis and Debug CyberResearch, Inc. maintains technical support lines staffed by experienced Applications Engineers and Technicians. There is no charge to call and we will return your call promptly if it is received while our lines are busy. Most problems encountered with data acquisition products can be solved over the phone. Signal connections and programming are the two most common sources of difficulty.
® CyberResearch Panel PCs FPC 1502 Series Intentionally Blank 64 ©Copyright 2004 CyberResearch, Inc.
® CyberResearch Panel PCs FPC 1502 Series Warranty Notice CyberResearch, Inc. warrants that this equipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect, CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
® CyberResearch Panel PCs FPC 1502 Series Intentionally Blank 66 ©Copyright 2004 CyberResearch, Inc.
CyberResearch, Inc. 25 Business Park Drive Branford, CT 06405 USA P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.