2.2 Rack Mounting
IMPORTANT! Ask yourself these questions before beginning installation:
1. Is sufficient power is available?
2. Is sufficient space is available to allow for proper airflow both inside and around
the display?
3. Is there a possibility the air temperature inside the rack will exceed the C
YRAQ
®
17’s rated specification? (Operating temperature: 32°F....122°F ((0°C....50°C)).)
3
NOTE: Though this product is designed to operate up to 122°F (45°C) with proper
ventilation, the life span of any electronic device is shortened when it is consistently
operated at high temperatures—keep rack temperature as low possible
4. Is there a possibility that the ambient humidity around the display will exceed its
rated specification? (Relative Humidity, non-condensing: 5%....95%)
2.2.1 Installation
3
NOTE Subsequent steps require two people.
1. Align holes in the front bezel with server rack mounting holes.
2. A second person should install the eight 10-32 x 1/2″ button head bolts through
rack-mounting holes in bezel and into the server rack (see Figure 1).
3. From inside rack, install and tighten mounting nuts (if applicable).