User`s manual

CyberResearch
®
Displays CYRAQ
®
21
2.3.2 Panel Mounting the Display
1. Panel cutout is 356mm H x 440mm W for landscape installation (Figure 6).
2. Install CYRAQ
®
in panel cutout. Ensure all studs clear cutout opening and
Poron
gasket on the rear of the unit is flush against panel (critical for NEMA
compliance).
3
NOTE: Steps 3 & 4 require a second person
3
NOTE: Steps 3 & 4 require a second person
3. Align studs on the CYRAQ with the holes in mounting plate from the rear of
panel as seen in Figure 6.
3. Align studs on the CYRAQ with the holes in mounting plate from the rear of
panel as seen in Figure 6.
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4. Also from rear of the panel, second person must install and tighten the fourteen
5. 10-32 mounting nuts.
Figure 6: Panel-Mount Landscape Installation
CyberResearch, Inc. 17
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024
Branford, CT USA www.cyberresearch.com