User`s manual
CyberResearch
®
Displays CYRAQ
®
21
CyberResearch, Inc. 19
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024
Branford, CT USA www.cyberresearch.com
2.4 Flush Panel-Mounting: CPxF/CPxR 21B
Prior to performing subsequent steps, ensure the panel-mounting location (including
panel thickness) is suitable for the C
YRAQ
®
21, and meets Environmental requirements
in Specifications section.
3
NOTE: Panel thickness should not exceed: .55" (14.1mm) Suggested panel thickness
is calculated based on standard CYRAQ 21 parts and dimensions, custom units may not
meet these specifications. Poron
™
gasket is installed by CyberResearch, Inc. on CPBF &
CPBR 21 models.
2.4.1 Panel Mounting the Monitor
1. Panel cutout is 401mm H x 487mm W for landscape installation (Figure 7).
2. Install the display in panel cut out. Ensure and Poron
™
gasket on the rear of the
unit is flush against panel (critical for NEMA compliance).
See Next Page For Illustration