User`s manual
CYRAQ
®
21 CyberResearch
®
Displays
18 ©Copyright 2006 CyberResearch, Inc
2.3.2 Panel Mounting the Monitor
1. Panel cutout is 356mm H x 440mm W for landscape installation (Figure 6).
2. Install CYRAQ
®
in panel cutout. Ensure all studs clear cutout opening and
Poron
™
gasket on the rear of the unit is flush against panel (critical for NEMA
compliance).
3
NOTE: Steps 3 & 4 require a second person
3. Align studs on the CYRAQ with the holes in mounting plate from the rear of
panel (as seen in Figure 6).
Important!
Do not exceed 30 in/lbs when tightening mounting nuts.
4. Also from rear of the panel, second person must install and tighten the fourteen
5. 10-32 mounting nuts.
Figure 6: Panel-Mount Landscape Installation