User`s manual
CyberResearch
®
CPU Cards CZGA LX-50
CyberResearch, Inc. 31
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024
Branford, CT USA www.cyberresearch.com
Supports NOGO function
Single 33 MHz Clock Input
+3.3V PCI I/F with +5V tolerant I/O buffers
+5V ISA I/F and core Power Supply
2.8 Environmental and Power Specifications
2.8.1 System Monitoring
The thermal inputs on the CZGA LX-50 Super I/O Enhanced Hardware Monitor monitor
the following fan speed
CPU FAN Speed
The voltage inputs on the CZGA LX-50 Super I/O Enhanced Hardware Monitor monitor
the following voltages:
Vcore
VccMem
+3.3 V
+5 V
+12 V
VBAT
5VSB
The values for the above environmental parameters are all recorded in the BIOS
Hardware Health Configuration menu.
2.8.2 Operating Temperature and Temperature Control
The maximum and minimum operating temperatures for the CZGA LX-50 are listed below.
Minimum Operating Temperature: 0ºC (32°F)
Maximum Operating Temperature: 60°C (140°F)
A cooling fan and heat sink must be installed on the CPU. Thermal paste must be
smeared on the lower side of the heat sink before it is mounted on the CPU. Heat sinks