User`s manual
CyberResearch
®
CPU Cards CZGA LX-50
CyberResearch, Inc. 211
25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024
Branford, CT USA www.cyberresearch.com
F.4 RAID Options
F.4.1 Create RAID 0 Striping for Performance
WARNING!
All data previously stored on the member drives of a RAID
configuration are destroyed during the RAID initialization process. If
“used” drives are used to create a RAID array, make sure the data has
been moved or backed up before creating a RAID array out of the disk
drives.
Step 1: Select “Create RAID 0 Striping for Performance”. Use the arrow keys to
highlight Create RAID 0 Striping for Performance and press E
NTER. A flashing
‘S’ appears on the Drive Menu where the member drives to be included in the
RAID 0 array can be chosen.
Step 2: Select RAID array drive members. Use the space bar to select members of the
RAID array. The flashing cursor changes to a lower case ‘s’ once any of the
connected disk drives has been selected. Follow the same method to select
another member drive.
Step 3: Confirm. The Create RAID 0(Y/N) confirm box appears. Press Y.
Step 4: Name the array. Enter a nickname for the created array. Upper and lower case
alphabetic, numeric, space, and underscore characters are all applicable for
naming an array.Step 0: