® PC Accessories ADAM 6521 5-Port Industrial 10/100 Mbps Ethernet Switch with Fiber Port USER’S MANUAL VER. 1.1 • JAN 2002 No part of this manual may be reproduced without permission CyberResearch , Inc. ® www.cyberresearch.com 25 Business Park Dr.
® CyberResearch PC Accessories ADAM 6521 ©Copyright 2002 All Rights Reserved. January 2002 The information in this document is subject to change without prior notice in order to improve reliability, design, and function and does not represent a commitment on the part of CyberResearch, Inc. In no event will CyberResearch, Inc.
® CyberResearch PC Accessories ADAM 6521 Intentionally Blank iv ©Copyright 2002 CyberResearch, Inc.
® CyberResearch PC Accessories ADAM 6521 Contents Chapter 1: Overview ......................................... 1 1.1 Introduction ..................................................................... 2 1.2 Features ........................................................................... 4 1.3 Specification ................................................................... 4 1.4 Package Checklist .......................................................... 5 Chapter 2: Installation ...................
® CyberResearch PC Accessories ADAM 6521 Figures Figure 2-1 Figure 2-2 Figure 2-3 Figure 2-4 Figure 2-5 Figure 2-6 vi ADAM 6521—Top Panel ........................................................... 9 ADAM 6521—Front Panel ........................................................ 9 ADAM 6521—Rear Panel ......................................................... 9 Panel Mounting ........................................................................ 10 Din Rail Mounting ....................................
® CyberResearch PC Accessories ADAM 6521 Tables Table 2-1 ADAM 6521 LED Definition ...................................................... 8 CyberResearch, Inc. 25 Business Park Drive Branford, CT USA vii P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
ADAM 6521 viii ® CyberResearch PC Accessories ©Copyright 2002 CyberResearch, Inc.
Chapter 1 Overview
® CyberResearch PC Accessories ADAM 6521 1.1 Introduction The ADAM 6521 is a five ports industrial-grade 10/ 100 Mbps Ethernet Switch with Fiber port. It allows you to expand your industrial network fast and costeffectively. The ADAM 6521 is a 5-port 10/100 Mbps Ethernet switch with Fiber port, which converts between 10/100Base-TX and 100Base-FX segments of the same network. Moreover, ADAM 6521 supports auto crossover to make it flexible networking environment, connecting to network by any port.
® CyberResearch PC Accessories ADAM 6521 With the function, ADAM 6521 any port can uplink to switch or hub devices by either straight through cable or crossover cable.Unlike other switches , it provides users with easy and flexible network connecting. Flexible mounting Due to its versatility and innovative design, the ADAM 6521 can be fixed in three ways: DIN rail, panel and piggyback mounting. Advanced surge protection for power input The ADAM 6521 supports wide-range voltage +10 ~ 30 VDC.
® CyberResearch PC Accessories ADAM 6521 • Supports 10/100 Base-TX and 100 Base-FX network • Supports full/half duplex flow control • Supports Integrated Loop-up engine • Supports MDI/MDI-X auto crossover • Provides broadcast storm protection • Supports +10 ~ 30 VDC voltage • Provides robust mountings: DIN rail, panel, piggyback • Supports operating temperature from -10 °C ~ 65 °C 1.3 Specification • Compatibility: IEEE 802.3, IEEE 802.
® CyberResearch PC Accessories ADAM 6521 • Case: ABS with captive mounting hardware • Placement: DIN-rail, panel mounting, piggyback stack • Operating Temperature: -10 to 65°C • Storage Temperature: -20 to 80°C • Operating Humidity: 20 to 95% (non-condensing) • Storage Humidity: 0 to 95% (non-condensing) 1.4 Package Checklist • ADAM 6521 • ADAM 6521 Manual • NYLON Din-rail Mounting Adapter • SECC panel mounting bracket CyberResearch, Inc.
ADAM 6521 6 ® CyberResearch PC Accessories ©Copyright 2002 CyberResearch, Inc.
Chapter 2 Installation
® CyberResearch PC Accessories ADAM 6521 In this chapter, you will be given an overview of the ADAM6521 hardware installation procedures. 2.1 Top / Front / Rear View There are six network status LEDs located on the top panel of ADAM 6521, each with its own specific function.
® CyberResearch PC Accessories ADAM 6521 Figure 2-1 ADAM 6521—Top Panel Figure 2-2 ADAM 6521—Front Panel Figure 2-3 ADAM 6521—Rear Panel CyberResearch, Inc. 25 Business Park Drive Branford, CT USA 9 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.
® CyberResearch PC Accessories ADAM 6521 2.2 Connecting the Hardware Next, we will explain how to find a proper location for your ADAM 6521, and then explain how to connect to the network, hook up the power cable, and connect to the ADAM 6521 Ethernet port. 2.2.1 Choosing a Location Due to its versatility and innovative design, the ADAM 6521 can be: • fixed to a panel mount • fixed to a DIN Rail. • Piggyback Stack Panel Mounting The ADAM 6521 can be attached to a wall using the included metal brackets.
® CyberResearch PC Accessories ADAM 6521 each bracket to a wall. DIN Rail Mounting You can mount the ADAM 6521 on a standard DIN Rail. First, using two screws, attach the metal plate to the DIN Rail bracket. Because the screw heads are beveled, the tops of the screws will be flush with the metal plate. Din Rail Mounting Brackets-Orientation of Metal Plates You can now screw the metal plate with the DIN rail bracket assembly to the bottom of the server is a more convenient way.
® CyberResearch PC Accessories ADAM 6521 Piggyback Stack ADAM 6521 can be stacked as seen in the figure below. Figure2-6 Piggyback Stack 12 ©Copyright 2002 CyberResearch, Inc.
® CyberResearch PC Accessories ADAM 6521 2.3 Network Connection 2.3.1 Connection to the devices The ADAM 6521 consists of one fiber and four RJ-45 ports. Each of the switch's twisted-pair ports can be used to connect a station or other device. Use a straight-through twisted-pair cable with RJ-45 connectors on both ends. The twisted-pair cable extended from a twisted-pair port is called a “twisted-pair segment,” and it can be up to 100 meters long.
ADAM 6521 ® CyberResearch PC Accessories 2.3.4 Power Connection You should take the following steps to connect ADAM 6521 power. 1. Connect the power cable to 2-pin connector 2. Connect power cable to power adapter Note: Please plug in a dust cover of fiber port to prevent from dust as you don't use fiber port. 14 ©Copyright 2002 CyberResearch, Inc.
® CyberResearch PC Accessories ADAM 6521 Product Service Diagnosis and Debug CyberResearch, Inc. maintains technical support lines staffed by experienced Applications Engineers and Technicians. There is no charge to call and we will return your call promptly if it is received while our lines are busy. Most problems encountered with data acquisition products can be solved over the phone. Signal connections and programming are the two most common sources of difficulty.
® CyberResearch PC Accessories ADAM 6521 Intentionally Blank 16 ©Copyright 2002 CyberResearch, Inc.
® CyberResearch PC Accessories ADAM 6521 Warranty Notice CyberResearch, Inc. warrants that this equipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect, CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
® CyberResearch PC Accessories ADAM 6521 Intentionally Blank 18 ©Copyright 2002 CyberResearch, Inc.
CyberResearch, Inc. 25 Business Park Drive Branford, CT 06405 USA P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.