Specifications
38
1.877.297.6 937
REPLACEMENT BATTERIES
Replacement Batteries
UPS Replacement Battery Specifications
Model Style UPS Model Type
Nominal
Voltage
Nominal
Amperage
Warranty
RB1270
BB/BP7.2-12 CP600LCD Sealed lead-acid 12V 7AH 18 mo.
RB1280
BB/BP8-12 CP685AVR, CP685AVRG, CP685AVRLCD Sealed lead-acid 12V 8AH 18 mo.
RB1280A
BB/HR1234W CP825LCD, CP800AVR, CP825AVRLCD, CP850AVRLCD Sealed lead-acid 12V 8AH 18 mo.
RB1290
BB/HR9-12 CP1000AVRLCD Sealed lead-acid 12V 9AH 18 mo.
RB1270X2
BB/SH1228W CP900AVR Sealed lead-acid 12V 7AH 18 mo.
RB1280X2A
BB/HR1234W CP1500AVRT, CP1500AVRLCD Sealed lead-acid 12V 8AH 18 mo.
RB0670X2
BB/BP7-6 OR500LCDRM1U Sealed lead-acid 6V 7AH 18 mo.
RB0690X2
BB/HR9-6 OR700LCDRM1U Sealed lead-acid 6V 9AH 18 mo.
RB0670X4
BB/BP7-6 OR1000LCDRM1U Sealed lead-acid 6V 7AH 18 mo.
RB0690X4
BB/HR9-6 OR1500LCDRM1U Sealed lead-acid 6V 9AH 18 mo.
RB0690X4A
BB/HR9-6 PR750LCDRM1U, PR1000LCDRM1U Sealed lead-acid 6V 9AH 18 mo.
RB1270X4
BB/BP7.2-12 OR1500LCDRM2U Sealed lead-acid 12V 7AH 18 mo.
RB1270X4A
BB/BP7.2-12 PR1000LCDRT2U, PR1500LCDRT2U, PR1000LCDRTXL2U Sealed lead-acid 12V 7AH 18 mo.
RB1270X4B
BB/SH1228WFR OR1500LCDRTXL2U Sealed lead-acid 12V 7AH 18 mo.
RB1290X4
BB/HR9-12 OR2200LCDRM2U Sealed lead-acid 12V 9AH 18 mo.
RB1290X4A
BB/HR9-12 PR2200LCDRT2U Sealed lead-acid 12V 9AH 18 mo.
RB1290X4B
BB/HR9-12FR OR2200LCDRTXL2U Sealed lead-acid 12V 9AH 18 mo.
RB1290X4D
BB/HR9-12FR
PR3000LCDRT2U, PR1000LCDRTXL2Ua, PR1500LCDRTXL2U,
PR2200LCDRTXL2U, PR3000LCDRTXL2U
Sealed lead-acid 12V 9AH 18 mo.
Features
•OEM Certified
•Leak Proof
•Maintenance-Free
•User-Installable
•Preassembled
•18-Month Warranty
Battery Life
The typical lifespan of internal UPS batteries is three to five years.
The number of discharge cycles a UPS system provides to connected
devices and the environment it operates in affect the number of years
can considered as a battery.
Maintenance
Regularly scheduled battery maintenance and monitoring can best
determine when batteries are nearing end-of-life, specifically, when they
can no longer supply 80% of their capacity. Inspection of a UPS and
initiation of a self-test, at least once a year, is recommended. Despite their maintenance-
free description (which simply means they do not require replacement fluid), sealed batteries
need scheduled preventive maintenance to check connections and remove corrosion, as well as
determine whether a battery is about to fail.
Replacement
A simple, cost-effective way to restore life to a CyberPower UPS system is to replace its internal
batteries with a CyberPower replacement battery cartridge. These sealed lead-acid batteries
are certified to meet or exceed original manufacturer specifications. These battery replacement
cartridges are preassembled for easy installation and are shipped in reusable packaging for
subsequent delivery of expired batteries to a suitable recycling center. All CyberPower batteries
include an 18-month warranty.