User Manual

Copyright © 2016 CyberPower Systems, Inc.
12
MODEL OR1000PFCRT2U OR1500PFCRT2U OR2200PFCRT2U
INPUT
Nominal Input Voltage 120Vac
Input Voltage Range 88Vac – 139Vac
Input Adjustable Voltage Range 86Vac – 142Vac
Input Frequency Range 60Hz +/- 3Hz
Input Plug Type NEMA 5-15P NEMA 5-20P
OUTPUT
Output Capacity 1000VA / 700W 1500VA / 1050W 2000VA / 1540W
Output Receptacles (8) NEMA 5-15R
(2) NEMA 5-20R,
(6) NEMA 5-15R
On Battery Output Voltage Pure Sine Wave 120Vac +/- 5%*
On Battery Output Frequency 60Hz +/- 1%
Transfer Time (Typical) 4ms
Overload Protection Internal Current Limiting
SURGE PROTECTION AND FILTERING
Lightning / Surge Protection Yes
Internet Ready (DSL / Phone /
FAX / Modem Protection)
RJ11/RJ45 (One In/One Out)
BATTERY
Replacement Battery Pack RB1290X2C RB1270X4G RB1290X4H
Sealed Maintenance Free Yes
Recharge Time (Typical) 10 hours from total discharge
WARNING DIAGNOSTICS
Indicators Power On, LCD Display
Audible Alarms On Battery, Low Battery, Overload
ENVIRONMENTAL
Operating Temperature 32°F to 104°F ( 0°C to 40°C)
Operating Relative Humidity 0 to 95% Non-Condensing
Storage Temperature F to 113°F ( -15°C to 45°C)
Storage Relative Humidity 0 to 95% Non-Condensing
MANAGEMENT
On-Device Features Manual Self-Test, Auto-Charge, Auto-Restart
Connectivity Ports (1) USB, (1) Serial port
SNMP/HTTP Networking Yes, with optional RMCARD205
Software PowerPanel® Business Edition
PHYSICAL
Dimensions (in) (mm) 2U Rack, 17” x 3.5” x 15.3” / 433 x 88 x 388 mm
Weight (lb) (kg) 37.5 lbs / 17kg 50.7 lbs / 23kg 57.3 lbs / 26kg
SAFETY
Conformance Approvals UL1778, cUL, FCC/Doc Class A
*For fully charged batteries.