User’s Manual Utility Series UPS UP1200 ADDITIONAL INSTALLATION TIPS CAN BE FOUND AT: www.cyberpowersystems.com/support.
TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS…………….……………………………………….………1 INSTALLING YOUR UPS SYSTEM…………………….………………………………….……2 - UNPACKING…… ………………………………………………………………..2 - HARDWARE INSTALLATION GUIDE…………………………………….……2 BASIC OPERATION…………………………………………...................................................2 - FRONT PANEL AND REAR PANEL DESCRIPTION....................................2 BATTERY REPLACEMENT AND STORAGE………………………………………….…...….4 - BATTERY REPLACEMENT PROCEDURE……………………………...
UP1200 Guaranteed Uninterruptible Power System IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS) This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate.
INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt. The box should contain the following: (1) UPS Unit; (1) User’s Manual for UPS; (1) Warranty Registration Card; TM TM (1) PowerPanel Software Disk; (1) User’s Manual for PowerPanel ; (1) Serial Interface Cable (DB-9); (1) Serial-to-USB cable; (1) Telephone Cable HARDWARE INSTALLATION GUIDE 1. Connect the equipment to your UPS outlets.
UP1200 Guaranteed Uninterruptible Power System ◆ Power Switch Press the power button to turn the UPS ON or OFF ◆ Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing “clean power”, free of surges and spikes ◆ Using Battery Indicator This illuminates during utility failure, indicating that the battery is supplying power to the battery-power supplied outlets.
BATTERY REPLACEMENT AND STORAGE Contact your dealer or call the number in this manual for information on battery replacement. The order numbers for the battery are as follows: BA-UP1200 for UP1200 CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. Service the battery under the supervision of personnel knowledgeable of batteries and their precautions. Keep unauthorized personnel away from batteries. CAUTION! Use only the specified type of battery.
UP1200 Guaranteed Uninterruptible Power System 8. Install the replacement battery by connecting the red wire to the positive (+) terminal of the battery and connecting the black wire to the negative (-) terminal of the battery. 9. Slide the battery back into the compartment. 10. Replace the cover and the 4 retaining screws. 11. Recharge the unit for 4 – 8 hours to ensure the UPS performs expected runtime. REMINDER: Batteries are consider HAZARDOUS WASTE and must be disposed of properly.
TROUBLESHOOTING Problem The UPS does not perform expected runtime. The UPS will not turn on. Outlets do not provide power to equipment PowerPanel™ is inactive (all icons are gray). Possible Cause Solution Batteries are not fully charged. Recharge the battery by leaving the UPS plugged in. Battery is slightly worn out. Contact CyberPower Systems at tech@cyberpowersystems.com The on/off switch is designed to prevent damage by rapidly turning it off and on. Turn the UPS off.
UP1200 Guaranteed Uninterruptible Power System TECHNICAL SPECIFICATIONS Model Capacity (VA) Capacity (Watts) Input Input Voltage Range Frequency Range Output On Battery Output Voltage On Battery Output Frequency Transfer Time (Typical) Overload Protection Surge Protection and Filtering Lightning / Surge Protection Internet Ready (DSL / Phone / FAX / Modem Protection) Physical Total # of UPS Receptacles Maximum Dimensions Weight Battery Sealed Maintenance Free Lead Acid Battery Replaceable Typical Recharge
DEFINITIONS FOR ILLUMINATED LED INDICATORS Condition Power On Using Battery Wiring Fault Circuit Breaker Alarm On Off Off Set Off Off On On/Off Set Two Beeps Utility Failure- The UPS is providing battery power to the Battery-Power Supplied outlets. Off On On/Off Set Rapid Beeps Utility Failure- The UPS is providing battery power. The rapid beeps indicate the battery will run out of charge within a few minutes. Overload- Occurs in the Full-time Surge Protection Outlets.
UP1200 Guaranteed Uninterruptible Power System LIMITED WARRANTY AND POWER CONTROL GUARANTEE In purchasing UP1200 in the United States or Canada, the original end user receives a Limited Warranty and CyberPower's Power Control Guarantee from Cyber Power Systems (USA), Inc. (for ease of reading, referred to as "CyberPower"). The Limited Warranty and the Power Control Guarantee are intended to be the original end-user's exclusive rights and remedies.
Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose, if applicable to the Product, is limited in duration to the period of ownership by the Initial Customer. This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product. NOTE: Some States and Provinces do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
UP1200 Guaranteed Uninterruptible Power System The Limited Warranty does not cover Connected Equipment, but as is explained below, to be covered under the Power Control Guarantee, the Connected Equipment must have been damaged due to a failure of the Product.
If the damage to Connected Equipment is covered by the Power Control Guarantee, CyberPower will (in addition to Limited Warranty remedies for the CyberPower Product itself) repair (or pay the costs of repair) or replace the Connected Equipment or, at the option of CyberPower, as permitted by law, pay to the Initial Customer the "Agreed Damage Amount" (up to the aggregate limits stated below) for all item(s) of Initial Customer's Connected Equipment.
UP1200 Guaranteed Uninterruptible Power System The Limited Warranty and the Power Control Guarantee Do Not Apply Unless The Initial Customer: 1. Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets (including compliance with electrical and safety codes of the most current electrical code (ANS/NFPA 70), without the use of any adapters, extension cords of other connectors. 2.
The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. Contact Information: CyberPower's address is 5555 12th Ave East, Suite 110, Shakopee, MN 55379 and its phone number is (952) 403-9500 or (877) 297-6937 (toll free). CyberPower is the warrantor under this Limited Warranty. You may also contact CyberPower on the Internet at www.cyberpowersystems.com.