User's Guide

Chapter 3. Using Your APS3
3.30
Changing the Pairing Between the APS3 Device
and Link
The APS device and link module in your kit were paired at the factory and will operate with
only that particular link module. You can change this pairing, so that you can use your APS
device with a different APS link module, or vice versa. Link modules for different CyberOptics
WaferSense or ReticleSense products, such as Auto Gapping Sensors (AGS), are not
interchangeable.
To pair an APS device and link module:
1. If you are changing the pairing of an APS device that is already paired with a link module,
first unplug the currently paired link module. You can’t pair an APS device with a new link
module while the currently paired link module is powered on.
2. Make sure the “Power “ LED is illuminated on the link module you want to pair, and
make sure the “Unit On” LED is illuminated on the APS device.
3. On the APS device, press and hold the “C” reset switch button until the “Connect
Pair” LED starts to blink rapidly (about four times per second).
4. On the link module, press and hold the “New Pair” button until the “Pair Status” and
Connection Status” LED lights start to blink rapidly (about four times per second).
The LEDs on the link module and the APS device will continue to blink for a few
seconds until the link and the APS device have established a new pairing, after which the
LEDs will be on and no longer blinking.