Specifications
Malaysia Reference Manual (MGCP/NCS Version)
Mediatrix 4100
223
Malaysia
The following parameters apply if you have selected Malaysia as location.
Table 151: Malaysia Parameters
Parameter Value On – Off Sequence (s) Elect. Levels
Dial Tone 425 Hz CONTINUOUS -14 dBm
Busy Tone 425 Hz 0.5 – 0.5 -18 dBm
Ringback Tone 425 Hz 0.4 – 0.2, 0.4 – 2.0 -16 dBm
Special Information Tone 900 Hz
1400 Hz
1800 Hz
1.0
1.0
1.0 – 1.0
-14 dBm
Stutter Dial Tone 425 Hz (0.1 – 0.1) x 3, CONTINUOUS -14 dBm
Confirmation Tone 425 Hz (0.1 – 0.1) x 3 End -14 dBm
Receiver Off Hook (ROH) Tone 1400+2060+2450+2600 Hz 0.1 – 0.1 -19 dBm
Message Waiting Indicator Tone 425 Hz (0.1 – 0.1) x 10, CONTINUOUS -14 dBm
Call Waiting Tone 440 Hz 0.3 -17 dBm
Alernative Call Waiting Tone 440 Hz
440 Hz
440 Hz
440 Hz
0.3
0.1 – 0.1, 0.1
0.1 – 0.1, 0.1 – 0.1, 0.1
0.1 – 0.1, 0.3 – 0.1, 0.1
-17 dBm
-17 dBm
-17 dBm
-17 dBm
Network Congestion Tone 425 Hz 0. – 0.25 -18 dBm
Ring AC: 45 VRMS, 20 Hz
DC: 15 Vdc
0.4 – 0.2, 0.4 – 2.0
Input Impedance 600 Ω
FXS Line Attenuation (Input) 0 dBr
FXS Line Attenuation (Output) -9 dBr