Specifications

Chapter 9 - Line Configuration Multiple Connections on Endpoints (Lines)
130
Mediatrix 4100
Permanent Administrative State
The permanent administrative state is applied every time the Mediatrix 4100 restarts.
To set a permanent administrative state:
1. In the ifAdminMIB, locate the ifAdminInitialAdminState variable.
This variable indicates the administrative state the current analog line will have after the Mediatrix
4100 restarts. It offers the following settings:
Multiple Connections on Endpoints (Lines)
The Mediatrix 4100 supports multiple connections on one endpoint. Under MGCP, it is now possible to create
multiple connections on a single endpoint, as long as there is only one active connection at a time.
Flash Hook Detection
The flash hook can be described as quickly depressing and releasing the plunger in or the actual handset-
cradle to create a signal indicating a change in the current telephone session. Services such as picking up a
call waiting, second call, call on hold, and conference are triggered by the use of the flash hook.
A flash hook is detected when the hook switch is pressed for a shorter time than would be required to be
interpreted as a hang-up.
Using the “flash” button that is present on many standard telephone handsets can also trigger a flash hook.
The Mediatrix 4100 allows you to set the minimum and maximum time within which pressing and releasing the
plunger is actually considered a flash hook.
To set flash hook parameters:
1. In the fxsMIB, set the following variables:
2. Restart the Mediatrix 4100 so that the changes may take effect.
Table 92: Permanent Lock Settings
Setting Description
unlocked Registers the line to the Call Agent.
locked The analog line is unavailable for normal operation. It cannot be used to
make and/or receive calls.
Table 93: Flash Hook Parameters
Variable Description
fxsFlashHookDetectionDelayMin Minimum time in ms the hook switch must remain pressed to
perform a flash hook.
Default Value: 100
fxsFlashHookDetectionDelayMax Maximum time in ms the hook switch can remain pressed to
perform a flash hook.
Default Value: 1200