Product specifications

Installing the VoIP Paging Amplifier
Restore the Factory Default Settings
VoIP Paging Amplifier Operations Guide 930185B CyberData Corporation
31
2.6 Restore the Factory Default Settings
When troubleshooting configuration problems, it is sometimes convenient to restore the device to a
known state.
Each Paging Amplifier is delivered with factory set default values for the parameters indicated in
Table 2-14. Use the RTFM switch on the Paging Amplifier face to restore these parameters to the
factory default settings.
When you use the RTFM switch, the factory default settings are restored for only the parameters
indicated in
Table 2-14. The other parameters in the current Paging Amplifier configuration will
remain unchanged.
To restore these parameters to the factory default settings:
1. Press and hold the RTFM switch for 20 seconds.
2. The Paging Amplifier will beep after one second. Continue to hold the switch until the Paging
Amplifier beeps again after 20 seconds.
3. Release the switch. The following occurs:
A voice message announces that the factory default settings are being restored.
Once the settings are restored, a voice message announces the restored default IP address:
192.168.3.10
A voice message announces that the Paging Amplifier is rebooting.
The Paging Amplifier reboots.
Table 2-14. Factory Default Settings
Parameter Factory Default Setting
IP Addressing static
IP Address 192.168.3.10
Web Access Username admin
Web Access Password admin
Subnet Mask 255.255.255.0
Default Gateway 192.168.3.1