Product specifications

VoIP Paging Gateway Operations Guide 930098E CyberData Corporation
2.3.5 Broadcast a test message to all paging zones
The Te st/ Rese t switch is located on the back of the VoIP Paging Gateway (see Figure 2-6). The Te st/
Reset switch enables testing to all paging zones and lets you restore the VoIP Paging Gateway to its
factory default settings.
Figure 2-6. Test/Reset Switch
Once the VoIP Paging Gateway is running and connected to a paging device, use the Test/R es et
switch to broadcast a test message to all of the zones in the paging system.
Note When the VoIP Paging Gateway has been configured and connected to a paging device, you
can also broadcast a test message to a paging zone that you specify. See
Section 2.4.5,
"Broadcast a Test Message to a Specific Paging Zone".
To use the Test/Reset switch to broadcast a test message to all zones, complete the following steps:
1. Press the end of a paper clip into the switch only until it beeps after one second.
2. Immediately release the switch. The VoIP Paging Gateway sends the audio message, via the
paging amplifier, to zone 00, which is the code for all zones, and the test message is broadcast to
all enabled paging zones. The round, green Paging light below the Status light blinks when the
page is in progress.
Test/Reset switch
Caution
Pressing the Test/Reset switch for longer than one second might restore the VoIP
Paging Gateway settings to the factory defaults.
GENERAL ALERT