10
Figure 2-6. Test/Reset Switch
Once the VoIP Paging Gateway is running and connected to a paging device, use the Test/Reset
switch to broadcast a test message to all zones in the paging system.
Note When the VoIP Paging Gateway
has been configured and connected to a paging device, you
can also broadcast a test message to a paging zone that you specify. Refer to Section 2.4.5,
"Broadcast a Test Message to a Specific Paging Zone"
To use the Test/Reset switch to broadcast
a test message to all zones:
1. Press the end of a paper clip into the switch only
until it beeps after one second.
2. Immediately re
lease the switch. The VoIP Paging Gateway sends the audio message, via the
paging amplifier, to zone 00, which is the code for all zones, and the test message is broadcast to
all enabled paging zones. The round, green Paging light below the Status light blinks when the
page is in progress.
CAUTION Pressing the Tes
t
/Reset switch for longer than one second might restore the VoIP
Paging Gateway settings to the factory defaults.
2.3.6 Restore the Factory Default Settings as Required
The VoIP Paging Gateway is delivered with factory set default values for the following parameters.
Use the Test/Reset switch on the back of the unit to restore these parameters to the factory default
settings. See Figure 2.3.5 for an illustration.
Note When you
perform this procedure, the factory default settings are restored for all the
following parameters.
Parameter Factory Default Setting
IP Addressing static
IP Address 192.168.3.10
Username admin