Product specifications

Installing the VoIP V2 Speaker
Configure the Speaker Parameters
Operations Guide 930274R CyberData Corporation
33
2. On the Nightringer Configuration page, enter values for the parameters indicated
in Ta b l e 2-9.
Web Page Item Description
Enable Nightringer When the nightringer is enabled, the ceiling speaker will
attempt to register a second extension with the SIP server.
Any calls made to this extension will play a ringtone.
Nightringer Settings
SIP Server Type the SIP server represented as either a numeric IP
address in dotted decimal notation.
Remote SIP Port Type the Remote SIP Port number (default 5060)
(8 character limit).
Local SIP Port Type the Local SIP Port number (default 5060)
(8 character limit).
Note: Th
is value cannot be the same as the Local SIP Port*
found on the SIP Configuration Page.
User ID Type the Us
er ID (up to 64 alphanumeric characters).
Authenticate ID Ty p e the A
uthenticate ID (up to 64 alphanumeric
characters).
Authenticate Password Type the A
uthenticate Password (up to 64 alphanumeric
characters).
Re-registration Interval (in seconds)* Type the SIP Registration lease time in minutes (default is
60 min
utes) (8 character limit). Re-registration Interval (in
seconds)*
Click the Sa
ve button to save your configuration settings.
Note: Y
ou need to reboot for changes to take effect.
Click on the Rebo
ot button to reboot the system.
3. After changing the parameters, click on the Save button.
Table 2-9. Nightringer Configuration Parameters