Product specifications

Implementing the VoIP V3 Zone Controller
Configuring the VoIP Zone Controller
Operations Guide 930446E CyberData Corporation
25
2. On the Nightringer Configuration page, enter values for the parameters indicated
in Table 2-9.
3. After changing the parameters, click on the Save button.
4. Click Reboot for the new settings to take effect.
Table 2-9. Nightringer Configuration Parameters
Web Page Item Description
Enable Nightringer When the nightringer is enabled, the unit will attempt to register a
second extension with the SIP server. Any calls made to this
extension will play a ringtone.
Nightringer Settings
SIP Server Type the SIP server represented as either a numeric IP address in
dotted decimal notation.
Remote SIP Port Type the Remote SIP Port number (default 5060)
(8 character limit).
Local SIP Port Type the Local SIP Port number (default 5061)
(8 character limit).
Note: This value cannot be the same as the Local SIP Port found
on the SIP Configuration Page.
User ID Type the User ID (up to 64 alphanumeric characters).
Authenticate ID Ty pe the Authenticate ID (up to 64 alphanumeric characters).
Authenticate Password Type the Authenticate Password (up to 64 alphanumeric
characters).
Re-registration Interval (in seconds) Type the SIP Registration lease time in seconds (default is 60
minutes) (8 character limit). Re-registration Interval (in seconds)
Play audio on ports When selected, a user-defined audio file is sent to the specified
port(s) when the night ringer is activated.
Click the Save button to save your configuration settings.
Note: You need to reboot for changes to take effect.
Click on the Reboot button to reboot the system.